Item
Specifications
Copy path (connection between storage systems)
Direct connection and remote connection
The maximum configurable capacity (per storage system) (*1)
3,072TB (ETERNUS DX500 S4/DX500 S3)
8,192TB (ETERNUS DX600 S4/DX600 S3)
Maximum number of TFO groups (per ETERNUS DX)
32
Failover
Automatic
¡
Manual
¡
Failback
Automatic
¡
Manual
¡
Automatic failover triggers
ETERNUS DX/AF failure
¡
Power failure/shutdown
¡
RAID failure/RAID blockage
¡
CA port link down
¡
Storage Cluster Continuous Copy (*2)
¡
¡
: Possible,
´
: Not possible
*1: The total available capacity of TFOVs for a ETERNUS DX can be expanded by setting an expansion for the
total capacity of TFOVs. If the installed memory is not sufficient, the expansion setting cannot be per-
formed.
For details on setting an expansion for the total capacity of TFOVs, refer to "ETERNUS CLI User's Guide".
*2: Storage Cluster Continuous Copy is an ETERNUS DX/AF function that performs a copy on the Primary storage
and the Secondary storage simultaneously, and achieves consistency between the two storage systems.
This is achieved by operating Advanced Copy from a TFOV to a TFOV.
•
After an error occurs in the Primary storage or RAID group, while the Primary storage is being switched to
the Secondary storage (max. 10 seconds), the Primary and Secondary storage cannot be accessed. There-
fore, business applications are expected to have a maximum I/O delay response of 10 seconds.
•
Data mirroring between the Primary storage and the Secondary storage is performed by the Storage Cluster
during normal operations. When a Write is performed from the server to the Primary storage, data is also
transferred to the Secondary storage, and after the transfer is complete a Write completion is returned to
the server. Therefore, when the Storage Cluster is installed, the response degrades during a Write compared
to an environment without the Storage Cluster.
•
Using OPC or QuickOPC for Advanced Copy from a TFOV is recommended.
•
In environments that use an iSCSI configuration, a switchover of the storage systems that is required for a
failover or a failback takes from 30 seconds to 120 seconds to be complete. Server I/O must also be restar-
ted in some cases.
•
The connection interface of business servers is FC or iSCSI (cannot be mixed). In addition, the switch con-
nection topology is supported.
•
For details on the required environment for the Storage Cluster (OS, HBA, multipath driver, and cluster soft-
ware), refer to "Support Matrix".
3. SAN Functions
Stable Operation via Load Control
127
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
P3AM-7722-25ENZ0
Summary of Contents for ETERNUS DX500 S3/DX600 S3
Page 218: ......