Powering off sequence
1
Shutdown of all the servers
2
Shutdown of all the server UPS units
3
Issuance of command to turn off the ETERNUS DX from the power synchronized unit
4
ETERNUS DX shutdown
Refer to the manual that is provided with a power synchronized unit for details about connection configurations
with power synchronized units and required settings.
Power Synchronized Connections (Wake On LAN)
By using Wake On LAN, an instruction to power on the storage system can be issued via the LAN.
"Magic packet" is sent by the utility software for Wake On LAN. The ETERNUS DX detects this packet and the pow-
er is turned on.
Figure 106 Power Supply Control Using Wake On LAN
Administration
Terminal
LAN
MN T
MN T
ETERNUS DX
CM#0
CM#1
2
1
Powering on sequence
1
A power on instruction is issued to the ETERNUS DX via the LAN.
2
ETERNUS DX startup
4. Connection Configuration
Power Synchronized Connections
166
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)