-15-
WARNING
WARNING
WARNING
WARNING
(1) This equipment is designed for splicing the optical glass fiber for
telecommunication. Do not attempt to splice any other types of fibers
or any other materials.
(2) Safety glasses should always be worn during the fiber preparation
and the splicing process. A glass fiber fragment can be extremely
dangerous if it comes into contact with the eye, skin, or is ingested.
(3) Use only the power cord attached. An improper power cord may
cause fire and/or equipment damage.
(4) The appliance inlet is used to disconnect the power cord when
using the equipment. Be sure to position the equipment so that it is
easy to disconnect the power cord.
(5) If the side ventilation holes are covered, high temperature inside
the equipment may result in damage. Confirm the clearance of 2
inches between the ventilation holes and wall when placing the
equipment.
(6) Check the AC or DC power source before turning on the equipment.
Proper power source is AC100-240V, 50-60Hz (Max.3A). Using power
source out of the proper range can cause personal injury and/or
equipment damage.
(7) When using an AC power generator, check AC output voltage with
a tester which can measure AC voltage. The AC output voltage from
the generator must be within AC100-240V, 50-60Hz. Generating
wrong high voltage above the specification is a common fault.
Measuring the AC output voltage is necessary before every use.
(8) Never operate the equipment in an environment where flammable
liquids, or vapor exists. Extremely dangerous fire and explosion may
be resulted in with the splicer's electrical arc under such an
environment.
(9) During arc discharge, the electrodes generate very high voltage.
The following measures will prevent personal injury and/or equipment
damage from the high electrical voltage.
-Make sure no water or liquid is present on the equipment.
-Never touch the electrodes.
-Before operation, connect the equipment to the electrical ground
(earth).
-When using an AC power source, use the AC power cord attached. It
connects to electrical ground through the third pin of the AC plug.
-Make sure the power switch is off when the power cord is plugged in
or out.
-Turn the power switch off and disconnect the power cord before the
electrodes, the fuse or the up/down mirror is replaced.
Summary of Contents for FSM-20PMII
Page 1: ...II ...
Page 2: ... 1 1 GENERAL 1 GENERAL 1 GENERAL 1 GENERAL ...
Page 4: ... 3 2 CONSTRUCTION 2 CONSTRUCTION 2 CONSTRUCTION 2 CONSTRUCTION ...
Page 15: ... 14 4 OPERATION 4 OPERATION 4 OPERATION 4 OPERATION ...
Page 18: ... 17 Hear is Flowchart page 1 ...
Page 19: ... 18 Hear is Flowchart page 2 ...
Page 42: ... 41 5 MENU COMMANDS 5 MENU COMMANDS 5 MENU COMMANDS 5 MENU COMMANDS ...
Page 58: ... 57 7 OHTERS 7 OHTERS 7 OHTERS 7 OHTERS ...
Page 66: ... 65 8 MAINTENANCE 8 MAINTENANCE 8 MAINTENANCE 8 MAINTENANCE ...
Page 80: ... 79 9 TROUBLE SHOOTING 9 TROUBLE SHOOTING 9 TROUBLE SHOOTING 9 TROUBLE SHOOTING ...
Page 88: ... 5 6 2 0 0 0 2 0 0 0 5 5 3 1 2 1 26 6 20 5 2 0 0 2 0 0 9 A 2 6 3 0 0 0 0 2 3 A 2 6 8 0 0 1 ...