-24-
4.2.6 Automatic Splicing Procedure
The automatic splice procedure is described as below.
1. Confirmation of the "READY" message
Check "READY" message is displayed on
the monitor (Display 1). Press the
"RESET" key to enter the "READY" state
if the "READY" message is not displayed.
2. Initial Gap Setting, Cleaning Arc and
Cleave Angle Check
Press the "SET" key to start splicing
process.
(1) Starting the Initial Gap Setting
At first, the splicer move forward.
(Display 2).
(2) Cleaning Arc
During the fiber forward motion, a
short Arc occurs to clean the fiber
surface.
(3) Initial Gap Setting
The proper gap between fiber ends is
set.
(4) Cleave Angle Check
After the gap setting, the cleave
angle is measured and displayed on
the monitor. (Display 3)
[NOTE] The splicer will be in a PAUSE state after gap setting if "PAUSE1" is
"ON" in the "CONDITION SET." menu. In the pause state. "CHECK
FIBER" message appears on the monitor. (Display 3)
(Concerning "PAUSE1" function, see Section 5.2.)
P1-PP
READY (X )
Display 1
P1-PP
225
0.7 0.2
CHECK FIBER (X)
Display 3
P1-PP
GAP SETTING (X )
Display 2
Summary of Contents for FSM-20PMII
Page 1: ...II ...
Page 2: ... 1 1 GENERAL 1 GENERAL 1 GENERAL 1 GENERAL ...
Page 4: ... 3 2 CONSTRUCTION 2 CONSTRUCTION 2 CONSTRUCTION 2 CONSTRUCTION ...
Page 15: ... 14 4 OPERATION 4 OPERATION 4 OPERATION 4 OPERATION ...
Page 18: ... 17 Hear is Flowchart page 1 ...
Page 19: ... 18 Hear is Flowchart page 2 ...
Page 42: ... 41 5 MENU COMMANDS 5 MENU COMMANDS 5 MENU COMMANDS 5 MENU COMMANDS ...
Page 58: ... 57 7 OHTERS 7 OHTERS 7 OHTERS 7 OHTERS ...
Page 66: ... 65 8 MAINTENANCE 8 MAINTENANCE 8 MAINTENANCE 8 MAINTENANCE ...
Page 80: ... 79 9 TROUBLE SHOOTING 9 TROUBLE SHOOTING 9 TROUBLE SHOOTING 9 TROUBLE SHOOTING ...
Page 88: ... 5 6 2 0 0 0 2 0 0 0 5 5 3 1 2 1 26 6 20 5 2 0 0 2 0 0 9 A 2 6 3 0 0 0 0 2 3 A 2 6 8 0 0 1 ...