4.0
Installation
4.10 Installation and positioning
WARNING
Cold units: The propane refrigerant is highly flammable.
All safety precautions must be followed.
WARNING
Position the unit on a flat and horizontal surface.
A temporally inclined plane of maximum 5° is allowed.
•
Place the unit level on a sufficiently sturdy floor.
•
Keep the weight of the unit in mind.
•
Use a level-ling instrument to level the unit by adjusting the unit’s legs.
(Refer to next page)
•
MCC cold: Please take notice of label with minimum space required
•
Be sure that the personnel have sufficient room to work with the unit.
•
Keep a distance of at least 150 mm (6 inch) between the back wall and the unit.
•
Do not position a unit near a doorway, a ventilation device or a refrigerator in order
to avoid any negative effects on the unit’s operation by a cold airflow.
The unit is designed for a maximum draft of 0.2 m/s (0.65 ft./sec).
•
Do not place the unit into direct sunlight.
•
Be sure that the ambient temperature for cold models remains between
10 ºC - 25 ºC (50 ºF - 77 ºF) and that the relative air humidity remains below 60%.
Cold units have been designed to operate at climate class 3 (according ISO 23953).
•
Hot units should not be used below 20 ºC (68 ºF) ambient temperatures.
•
Keep the plinth free from any obstacles to ensure ventilation.
Summary of Contents for MCC 120
Page 4: ...Page 4 Service Manual MCC Cold US 20220700...
Page 20: ...Page 20 Service Manual MCC Cold US 20220700 4 1 Connecting drain or evaporation tray...
Page 21: ...Service Manual MCC Cold US 20220700 Page 21 4 1 Connecting drain or evaporation tray...
Page 30: ...Page 30 Service Manual MCC Cold US 20220700 5 1 MCC 90 Drop in Dimensions Self Serve...
Page 39: ...Service Manual MCC Cold US 20220700 Page 39 6 0 Installation Front door section first version...
Page 83: ...Service Manual MCC Cold US 20220700 Page 83...
Page 87: ...Service Manual MCC Cold US 20220700 Page 87...
Page 89: ...Service Manual MCC Cold US 20220700 Page 89 Page intentionally left blanc...
Page 102: ...Page 102 Service Manual MCC Cold US 20220700 13 0 Electrical schematics MCC Cold first version...
Page 104: ...Page 104 Service Manual MCC Cold US 20220700 13 2 Electrical wiring MCC Cold Self Serve N L...