PAO
Alarm exclusion time after instrument switch on, after a power failure
0
hours
dAO
Temperature alarm exclusion time after defrost
0
min
OAO
Alarm signaling delay after digital input disabling
0
hours
tdO
Alarm activation delay time open door
0
hours
tAO
Temperature alarm signal delay time
30
min
dAt
Alarm for defrosting ended due to time out
n
flag
rLO
External alarm locks controller
n
flag
AOP
Alarm outp polarity
1
num
SA3
Probe Pb3 Alarm Setpoint
30
°C
dA3
Probe Pb3 alarm activation differential
1
°C
Cool protection ("CPr" folder)
CPS
Cool protection setpoint
-10
°C
CPd
Cool protection differential
1
°C
CPt
Time that the temperature remains below the cool protection setpoint
0
min
Lights & digital inputs ("Lit" folder)
dOd
Enable utility switch-off on activation of door switch
0
num
dad
Activation delay for digital input
0
min
dCO
Compressor deactivation delay after door opened
0
min
dCd
Fans activation delay after door closed
10
secs
Pressure switch ("Pre" folder)
Pen
Number of errors allowed for general pressure switch input
5
num
PEI
Minimum/maximum pressure switch error count interval
1
min
Pet
Delay in activating compressor after pressure switch deactivation
0
min
Deep cooling ("dEC" folder)
dCA
Enable deep cooling
0
num
dCS
Deep cooling setpoint
-1
°C
tdC
Deep cooling duration
0
min
dcc
Defrost delay after deep cooling
0
min
Sid
Deep cooling start threshold
12
°C
toS
Over-threshold time for deep cooling start
5
min
Energy saving ("EnS" folder)
Est
Energy Saving mode
0
num
ESA
AUX output status in energy saving mode
0
num
ESF
Night mode activation for fans
y
flag
Cdt
Door close time
60
min*10
ESo
Cumulative door open time for disabling Energy Saving mode
0
num
OSP
Offset on setpoint
0,5
°C
OdF
Intervention differential correction
4
°C
dnt
Duration of night mode
10
hours
dFt
Duration of fast cooling mode
1
hours
SPn
Night mode setpoint
1
°C
8.1
Parameter MCC Cold Settings (Self Serve)
Summary of Contents for MCC 120
Page 4: ...Page 4 Service Manual MCC Cold US 20220700...
Page 20: ...Page 20 Service Manual MCC Cold US 20220700 4 1 Connecting drain or evaporation tray...
Page 21: ...Service Manual MCC Cold US 20220700 Page 21 4 1 Connecting drain or evaporation tray...
Page 30: ...Page 30 Service Manual MCC Cold US 20220700 5 1 MCC 90 Drop in Dimensions Self Serve...
Page 39: ...Service Manual MCC Cold US 20220700 Page 39 6 0 Installation Front door section first version...
Page 83: ...Service Manual MCC Cold US 20220700 Page 83...
Page 87: ...Service Manual MCC Cold US 20220700 Page 87...
Page 89: ...Service Manual MCC Cold US 20220700 Page 89 Page intentionally left blanc...
Page 102: ...Page 102 Service Manual MCC Cold US 20220700 13 0 Electrical schematics MCC Cold first version...
Page 104: ...Page 104 Service Manual MCC Cold US 20220700 13 2 Electrical wiring MCC Cold Self Serve N L...