Page 10
Service Manual MCC Cold US 20220700
2.0
Detailed description
2.1 Technical description Self Serve
Panels are made of galvanized steel plating, stainless steel and/or aluminum.
Some of the visible internal and external parts have been provided with a powder coating.
Glass used is tempered.
Unit can be moved by means of a pallet truck.
Product contact parts are made of stainless steel AISI 304 or AISI 430 and tempered glass.
2.2 Cold units Self Serve:
(OmiCold Air flow technology)
Cooling is achieved by means of a thermostatic temperature-controlled cold airflow.
Cold air is passed via the back and shelves over the products.
Between price rail and child glass an opening exists which is vital for the airflow
inside the unit.
Price rail must always be kept in place .
For MCC Cold SS:
Price rail is integrated part of air guidance inside the unit.
Removing the price rail will result in a bad functioning MCC
Self-serve models have an additional set of fans mounted in the top to create a stable air curtain on
the open side of the cabinet to minimize the infiltration of warm ambient air. The air on the front side
passes through the suction grid in the bottom of the unit.
Temperature of the airflow is controlled electronically.
The electronically controlled thermostat is factory pre-programmed.
Set temperature can be changed from -6 ºC to +0 ºC (21.2 ºF to 32 ºF).
The units can be connected to a fixed drainage system or an optional evaporation tray to evacuate
Condensation water.
One LED-module per level provides lighting of the products.
Lighting and cooling are switched on simultaneously
Self-serve models can be fitted with an optional night curtain.
Air flow Self Serve
Air flow Full Serve
Summary of Contents for MCC 120
Page 4: ...Page 4 Service Manual MCC Cold US 20220700...
Page 20: ...Page 20 Service Manual MCC Cold US 20220700 4 1 Connecting drain or evaporation tray...
Page 21: ...Service Manual MCC Cold US 20220700 Page 21 4 1 Connecting drain or evaporation tray...
Page 30: ...Page 30 Service Manual MCC Cold US 20220700 5 1 MCC 90 Drop in Dimensions Self Serve...
Page 39: ...Service Manual MCC Cold US 20220700 Page 39 6 0 Installation Front door section first version...
Page 83: ...Service Manual MCC Cold US 20220700 Page 83...
Page 87: ...Service Manual MCC Cold US 20220700 Page 87...
Page 89: ...Service Manual MCC Cold US 20220700 Page 89 Page intentionally left blanc...
Page 102: ...Page 102 Service Manual MCC Cold US 20220700 13 0 Electrical schematics MCC Cold first version...
Page 104: ...Page 104 Service Manual MCC Cold US 20220700 13 2 Electrical wiring MCC Cold Self Serve N L...