Page 66
Service Manual MCC Cold US 20220700
9
.0
Trouble Shooting
9.0.0 Problems which can be checked by user
Each user can check the following points as mentioned in the user manual:
•
Is the power supply OK?
•
Check the fuses and the earth leakage switch in the meter cup board.
•
Are all the switches in the correct “on” position?
Item
Malfunction
Possible action
Unit
Unit does not work
•
Check the power supply.
•
Are all switches in the correct position.
Unit
Display shows error code
•
Contact your supplier or service agency.
Lamp
Does not light up
•
Switch ON.
Mains cord
Damaged
•
Replace.
Window
Damaged
•
Replace.
9.0.1 Cold units
WARNING
All service operations on the refrigeration system and gas charging must be performed by
fully certified and qualified persons, in a well ventilated environment.
9.0.2 Replace the mains cord
WARNING
Hazardous electrical voltage.
If the mains cord is damaged, it must be replaced by a fully certified and qualified person,
in order to avoid hazards.
10.0.3
Error codes and solutions
See page 69
NTC
sensor
testing (Cold Unit)
1.
Remove wiring from the sensor.
2.
Connect a temperature tester to the probe of the sensor for comparison.
3.
Test the probe with a Ohm tester (range 5kΩ til 100kΩ).
Temperature
Resistance
kΩ
⁰F
⁰C
+/- 500 Ohms
-4
-20
67,77
14
-10
42,47
32
0
27,28
50
10
17,96
68
20
12,09
77
25
10,00
Summary of Contents for MCC 120
Page 4: ...Page 4 Service Manual MCC Cold US 20220700...
Page 20: ...Page 20 Service Manual MCC Cold US 20220700 4 1 Connecting drain or evaporation tray...
Page 21: ...Service Manual MCC Cold US 20220700 Page 21 4 1 Connecting drain or evaporation tray...
Page 30: ...Page 30 Service Manual MCC Cold US 20220700 5 1 MCC 90 Drop in Dimensions Self Serve...
Page 39: ...Service Manual MCC Cold US 20220700 Page 39 6 0 Installation Front door section first version...
Page 83: ...Service Manual MCC Cold US 20220700 Page 83...
Page 87: ...Service Manual MCC Cold US 20220700 Page 87...
Page 89: ...Service Manual MCC Cold US 20220700 Page 89 Page intentionally left blanc...
Page 102: ...Page 102 Service Manual MCC Cold US 20220700 13 0 Electrical schematics MCC Cold first version...
Page 104: ...Page 104 Service Manual MCC Cold US 20220700 13 2 Electrical wiring MCC Cold Self Serve N L...