background image

SERVICE MANUAL

ER-A

457

ONLINE COMMUNICATION FUNCTION

ELECTRONIC CASH
REGISTER

MODEL

MODEL

 ER-A

457

(For "V" version)

SHARP CORPORATION

This document has been published to be used 
for after sales service only.
The contents are subject to change without notice.

Parts marked with "

" is important for maintaining the safety of the set. Be sure to replace these parts with specified

ones for maintaining the safety and performance of the set.

CHAPTER 1.  OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

CHAPTER 2.  SYSTEM CONFIGURATION . . . . . . . . . . . . . . . . . . . . . .  1

CHAPTER 3.  SPECIFICATIONS OF RS-232 INTERFACE . . . . . . . . .  2

CHAPTER 4.  SIGNAL CONNECTION DIAGRAM . . . . . . . . . . . . . . . . .  2

CHAPTER 5.  RS-232 PROTOCOL . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

CHAPTER 6.  CONTROL SIGNAL SEQUENCE . . . . . . . . . . . . . . . . .  11

CHAPTER 7.  DATA BLOCK FORMAT . . . . . . . . . . . . . . . . . . . . . . . .  14

CHAPTER 8.  ONLINE APPLICATION . . . . . . . . . . . . . . . . . . . . . . . . .  14

CONTENTS

Summary of Contents for ER-A457

Page 1: ...ce Parts marked with is important for maintaining the safety of the set Be sure to replace these parts with specified ones for maintaining the safety and performance of the set CHAPTER 1 OVERVIEW 1 CHAPTER 2 SYSTEM CONFIGURATION 1 CHAPTER 3 SPECIFICATIONS OF RS 232 INTERFACE 2 CHAPTER 4 SIGNAL CONNECTION DIAGRAM 2 CHAPTER 5 RS 232 PROTOCOL 4 CHAPTER 6 CONTROL SIGNAL SEQUENCE 11 CHAPTER 7 DATA BLOC...

Page 2: ...upport mainly the following functions a The function of ONLINE 1 Down load of ECR data ECR PC 2 Up load of ECR data ECR PC 3 RJE Remote job entry function ECR PC 4 ELECTRONIC MAIL function ECR PC CHAPTER 2 SYSTEM CONFIGURATION 1 GENERAL Online data communication is allowed only when RS232 channel presets at PGM2 mode 2 Online data communication a Direct connection Host computer ER A457 Host comput...

Page 3: ...er The table shows the relationship between the data rate and the rec ommended cable length Data rate Recommended cable length 19 200 bps 3 75 meters 9 600 bps 7 5 meters 4 800 bps 15 meters 2 400 bps 30 meters 1 200 bps 60 meters CHAPTER 4 SIGNAL CONNECTION DIAGRAM 1 Connection between the master Host and Satellite SD TRANSMITTED DATA RD RECEIVED DATA DTR DATA TERMINAL READY DSR DATA SET READY RT...

Page 4: ...TA SET READY RTS REQUEST TO SEND DCD DATA CARRIER DETECTOR CTS CLEAR TO SEND CI CALLING INDICATOR FG FRAME GROUND SD SD RD SG RD 3 2 4 6 7 1 8 5 2 3 20 6 4 8 5 7 RTS DCD DTR DSR CTS CI 22 9 SG RTS DCD DTR DSR CTS CI FG 1 FRAME GROUND is connected to the shield of the cable MODEM TERMINAL 25PIN D SUB 9PIN D SUB 3 ...

Page 5: ...h 1001 9 39h 1010 A 41h 1011 B 42h 1100 C 43h 1101 D 44h 1110 E 45h 1111 F 46h CHAPTER 8 ONLINE application 1 ONLINE preset 1 SRV programming NONE 2 PGM programming Job PGM MODE programming for online operation 2690 The assignment of RS232 channel by each devices 6110 Programming of the terminal number 6111 Programming of the modem control 6112 Programming of the transmission data rate Bau rate 61...

Page 6: ...mming of the transmission baud rate 6112 A Transmission baud rate Transmission baud rate 6112 A 300 bps 0 600 bps 1 1200 bps 2 2400 bps 3 4800 bps 4 9600 bps 5 19200 bps 6 JOB 6113 MRS 002013 Programming of the start and end code XXX Start code 02H STX YYY End code 0DH CR JOB 6115 MRS 007 Programming at the time out value XXX 1 255 sec JOB 6110 Online preset reading 6111 AB 0 x TL 6112 A 0 x TL 61...

Page 7: ... stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION Information Systems Group Quality Reliability Control Center Yamatokoriyama Nara 639 11 Japan 2001 April Printed in Japan ...