INTRODUCTION

Your 5330X-403 is a counter with an eight-digit LCD
display. A programmable scaler and decimal point allow
for display in any engineering unit.

Durant

®

RST

8-d ig it  LCD
Display

 

Reset/ 
P rog ram m ing
Bu tton

P rog ram m ing
Bu tton 

P la stic
fro nt p anel
sealed  to
m eet
NE M A 4X  

F ro nt  View

5   E n a ble /R

5   E n a ble /R

R S T  4

IN  A  3

IN  B  2

G N D   1

6   D C   C om m o n

7   + 1 0 -3 0 VD C

Program  
Ena ble

R eset Inpu t

Q u adrature A

Q u adrature B

G ro un d

Re ar V iew

APPLICATIONS

Certain programming and wiring choices must be made to
accomplish your application. We recommend the follow-
ing sequence:

1.

Answer the following questions:
• What type of sensor will be used?
• To what engineering units should the counter be

scaled?

• How many pulses per item is the sensor

providing?

• Is a decimal point needed on the display?

2.

Calculate the scale factor.

MOUNTING

PROGRAM MODE

To enter the program mode, a connection must be made
between terminals 1 and 5 (see page 4).

Durant

®

2.677" (67mm )

1.299" 

(33m m)

Recomm ended 

Panel Cutout

Durant

Install m ounting clip

Gasket Installed?

Screens

There are four program-mode screens in the 5330X-403.
Upon entering the setup mode, the counter will display

screen 1. Press and hold the 

 key while repeatedly

pressing the 

 key to advance to successive screens.

           

Programming Screens

Screen 

 

          Function 

Count Scale Factor 

Count Decimal Point 

Reset to Offset Value 

Reset Key Enable / Disable 

OPERATION

Quadrature Counting

Quadrature is a bi-directional count mode requiring an in-
put signal at each of the totalizer’s two count inputs. Quadra-
ture counting is typically accomplished by using a quadra-
ture encoder as the count source although any two sen-
sors with single channel outputs may be used if the sen-
sors are positioned correctly. In either case, both sensor
outputs must produce pulses at the same frequency and
there must be a phase shift between the signals. The total-
izer recognizes  the phase shift and uses it to determine if
it should be counting up, or counting down. Finally, the
signal channels must alternate changes of state. This pro-
duces the four distinct input conditions from which the term
quadrature is derived. These conditions are off-off, on-off,
on-on, and off-on.

Quadrature Signal

Count Inputs

O ff

O n

O ff

O n

Count inputs A and B (terminals 3 and 2) are pulled down
to ground (terminal 1). The sensor must supply between
2.0 and 28 VDC at the count inputs for the totalizer to count.

The totalizer has high speed inputs only and is capable of
receiving pulses at 10kHz per channel if each signal is a
square wave and there is a 90° phase shift between the
two signals. For this reason, it is recommended that solid
state sensors (PNP output or NPN output with a pull-up
resistor) be used.

If the totalizer counts in the “wrong” direction at startup,
stop the process and switch the wires at terminals 2 and 3.
This will cause the totalizer to count in the “right” direction
when the process is re-started.

Summary of Contents for Durant Courier 5330 403 Series

Page 1: ... Key Enable Disable OPERATION Quadrature Counting Quadrature is a bi directional count mode requiring an in put signal at each of the totalizer s two count inputs Quadra ture counting is typically accomplished by using a quadra ture encoder as the count source although any two sen sors with single channel outputs may be used if the sen sors are positioned correctly In either case both sensor outpu...

Page 2: ...far right digit will be flashing Press the RST key until reaching the desired digit value Note Pressing and holding the RST key will cause the numbers to autoscroll Next press the key to move the flashing digit one place to the left Change this digit to the desired value with the RST key Repeat this process until all digits are set correctly Setting the count scale factor to 0 0000 will allow scal...

Page 3: ...erature specifications Do not mount this unit in a heavy vibration area BATTERYSAFETY The lithium battery that powers your device contains in flammable materials such as lithium organic solvent and other chemical ingredients Explosion or fire may result if the battery is not handled correctly To avoid an accident follow these guidelines Do not heat batteries above 95 C Do not recharge lithium batt...

Page 4: ...HALL EATON BE LIABLE FOR CLAIMS BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR NEGLIGENCE OR ANY OTHER DAMAGES WHETHERDIRECT IMMEDIATE FORESEEABLE CONSEQUENTIAL ORSPECIALORFORANYEXPENSESINCURREDBYREASONOF THE USE OR MISUSE SALE OR FABRICATION OF PRODUCTS WHICH DO OR DO NOT CONFORM TO THE TERMS AND CONDI TIONS OF THIS CONTRACT INDEMNIFICATION Buyer agrees to hold Eaton harmless from defend and...

Page 5: ...Durant Products 901 S 12th Street Watertown WI 53094 800 540 9242 920 261 4070 Fax 920 261 9097 www durant com ...

Page 6: ... Series Decimal Point 5 positions programmable DC COMMON Terminal 1 COUNT INPUTS A B Terminals 2 and 3 Inputs A B require a quadrature signal with a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed 0 to 10 kHz Min Low Time 50 microseconds Min High Time 20 microseconds The above times are with a 0 to 5V swing Input Impedance...

Reviews: