background image

CHAPTER 7. DATA BLOCK FORMAT

1. Basic format

        Start code : This code may not be provided.

Null is impermissible.

        End code : This code may not be provided.

Null or any same code as the start code is
not permissible.

When master reset is performed, the default is assumed:

    Start 

code 

02h

    End 

code 

0Dh

  Block consecutive No. : This number starts with 30h and cycles

like this: 30h, 31h — 39h, 30h, 31h (Ring
counter system)

  Check sum

: 2 bytes hex number 

Low-order 8-bit data of the complement of
2 for the sum of text data.

  RAM data:

: Even number of data that is obtained by

dividing one byte of RAM data into high-
order 4 bits and low-order 4 bits and con-
verting them to ASCII codes shown in the
code conversion table.

Code conversion table .

Print code (high-order or low-order 4 bits)

Line image

Bit image

Hexadecimal

ASCII

0000

0

30h

0001

1

31h

0010

2

32h

0011

3

33h

0100

4

34h

0101

5

35h

0110

6

36h

0111

7

37h

1000

8

38h

1001

9

39h

1010

A

41h

1011

B

42h

1100

C

43h

1101

D

44h

1110

E

45h

1111

F

46h

CHAPTER 8.  ONLINE application

1. ONLINE preset

1) SRV programming: NONE

2) PGM programming

Job#

PGM-MODE programming for online operation

2690

The assignment of RS232 channel by each devices.

6110

Programming of the terminal number

6111

Programming of the modem control

6112

Programming of the transmission data rate (Bau rate)

6113

Programming of the start and end code.

6115

Programming of time out value

6110

Online Preset reading

[JOB#2690] MRS = 0000

The assignment of RS232 channel by each devices.

X: 1

A:

On-line

2690-A

No

0

Yes (Channel No. = 8)

8

[JOB#6110] MRS = 000001

Programming of the terminal number

NK: Terminal No. = 0 to 999999

1) ID-ENQ :

10bytes

ENQ code (05h)

Terminal No. 000001-999999 (6 bytes)

EOT is set as dummy cahracters. (3 bytes)

2) ACK :

1 byte   06h

3) NAK :

1 byte   15h

4) EOT :

1 byte   04h

5) ENQ :

1 byte   05h

6) TEXT :

Data ASCII (max. 250 bytes)

Block consecutive No.

Start code

End code

Check sum

Example

Memory image

Line image

02

5A

F0

1

2

3

30h

32h

35h

41h

46h

30h

Transmission sequence

1

2

3

2690

X

X

X

ABCD

ST

TL

0

6110

NK

0

x

TL

– 14 –

Summary of Contents for ER-A457

Page 1: ...ce Parts marked with is important for maintaining the safety of the set Be sure to replace these parts with specified ones for maintaining the safety and performance of the set CHAPTER 1 OVERVIEW 1 CHAPTER 2 SYSTEM CONFIGURATION 1 CHAPTER 3 SPECIFICATIONS OF RS 232 INTERFACE 2 CHAPTER 4 SIGNAL CONNECTION DIAGRAM 2 CHAPTER 5 RS 232 PROTOCOL 4 CHAPTER 6 CONTROL SIGNAL SEQUENCE 11 CHAPTER 7 DATA BLOC...

Page 2: ...upport mainly the following functions a The function of ONLINE 1 Down load of ECR data ECR PC 2 Up load of ECR data ECR PC 3 RJE Remote job entry function ECR PC 4 ELECTRONIC MAIL function ECR PC CHAPTER 2 SYSTEM CONFIGURATION 1 GENERAL Online data communication is allowed only when RS232 channel presets at PGM2 mode 2 Online data communication a Direct connection Host computer ER A457 Host comput...

Page 3: ...er The table shows the relationship between the data rate and the rec ommended cable length Data rate Recommended cable length 19 200 bps 3 75 meters 9 600 bps 7 5 meters 4 800 bps 15 meters 2 400 bps 30 meters 1 200 bps 60 meters CHAPTER 4 SIGNAL CONNECTION DIAGRAM 1 Connection between the master Host and Satellite SD TRANSMITTED DATA RD RECEIVED DATA DTR DATA TERMINAL READY DSR DATA SET READY RT...

Page 4: ...TA SET READY RTS REQUEST TO SEND DCD DATA CARRIER DETECTOR CTS CLEAR TO SEND CI CALLING INDICATOR FG FRAME GROUND SD SD RD SG RD 3 2 4 6 7 1 8 5 2 3 20 6 4 8 5 7 RTS DCD DTR DSR CTS CI 22 9 SG RTS DCD DTR DSR CTS CI FG 1 FRAME GROUND is connected to the shield of the cable MODEM TERMINAL 25PIN D SUB 9PIN D SUB 3 ...

Page 5: ...h 1001 9 39h 1010 A 41h 1011 B 42h 1100 C 43h 1101 D 44h 1110 E 45h 1111 F 46h CHAPTER 8 ONLINE application 1 ONLINE preset 1 SRV programming NONE 2 PGM programming Job PGM MODE programming for online operation 2690 The assignment of RS232 channel by each devices 6110 Programming of the terminal number 6111 Programming of the modem control 6112 Programming of the transmission data rate Bau rate 61...

Page 6: ...mming of the transmission baud rate 6112 A Transmission baud rate Transmission baud rate 6112 A 300 bps 0 600 bps 1 1200 bps 2 2400 bps 3 4800 bps 4 9600 bps 5 19200 bps 6 JOB 6113 MRS 002013 Programming of the start and end code XXX Start code 02H STX YYY End code 0DH CR JOB 6115 MRS 007 Programming at the time out value XXX 1 255 sec JOB 6110 Online preset reading 6111 AB 0 x TL 6112 A 0 x TL 61...

Page 7: ... stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION Information Systems Group Quality Reliability Control Center Yamatokoriyama Nara 639 11 Japan 2001 April Printed in Japan ...

Reviews: