![Flexim FLUXUS G722ST-HT Operating Instruction Download Page 74](http://html1.mh-extra.com/html/flexim/fluxus-g722st-ht/fluxus-g722st-ht_operating-instruction_2304717074.webp)
7 Connection
7.6 Service interfaces
FLUXUS G722ST-HT
2021-09-01, UMFLUXUS_G722ST-HTV1-2EN
74
• Push the cable through cap nut, compression part, basic part and sealing ring (sealing ring: only for cable gland M20,
not for cable gland 1/2 NPS).
• Insert the cable into the housing of the transmitter.
• Push the cable through the ferrite nut.
• Prepare the cable (see the documentation provided by the manufacturer).
• Install the connector (see the documentation provided by the manufacturer).
• Insert the connector into the LAN interface.
• Position the cable in the housing as shown in Fig. 7.22.
• Fix the cable gland by screwing the cap nut onto the basic part.
• Fix the transducer cable by tightening the cable gland with the ferrite nut.
Fig. 7.23: Cable gland
1 – cap nut
2 – compression part
3 – basic part
4 – sealing ring (only for cable gland M20, not for cable gland 1/2 NPS)
5 – housing wall
6 – ferrite nut
2
1
3 4 5
6