10 Troubleshooting
FLUXUS G722ST-HT
2021-09-01, UMFLUXUS_G722ST-HTV1-2EN
102
If any problem appears which cannot be solved with the help of this operating instruction, contact our sales office and give
a precise description of the problem. Specify the type, the serial number and the firmware version of the transmitter.
The display does not work at all or fails regularly.
• Check the contrast setting of the transmitter or enter the HotCode
555000
to set the display to medium contrast.
• Make sure that the correct voltage is available at the terminals. The destined transmitter voltage is indicated on the
nameplate below the outer right terminal strip.
• If the power supply is OK, the transducers or an internal component of the transmitter are defective. The transducers and
the transmitter have to be sent to FLEXIM for repair.
An error is displayed in the status indication (symbol
).
• Press
to return to the main menu.
• Select the menu item
Special functions\System settings\Event log
.
• Press ENTER.
The error message list will be displayed.
Date and time are wrong, the measured values are deleted when the transmitter is switched off.
• If the date and the time are reset or wrong or the measured values are deleted after the transmitter has been switched off
and on again, the data backup battery has to be replaced. Send the transmitter to FLEXIM.
An output does not work.
• Make sure that the outputs are configured correctly. Check the function of the output. If the output is defective, contact FLEXIM.