![Flexim FLUXUS G722ST-HT Operating Instruction Download Page 44](http://html1.mh-extra.com/html/flexim/fluxus-g722st-ht/fluxus-g722st-ht_operating-instruction_2304717044.webp)
6 Mounting
6.2 Transducers
FLUXUS G722ST-HT
2021-09-01, UMFLUXUS_G722ST-HTV1-2EN
44
Mounting the rail with ratchet clasp
• Cut the tension strap to length (pipe circumf at least 120 mm).
• Insert approx. 100 mm of the tension strap into part (1) and (2) of the ratchet clasp (see Fig. 6.39 a).
• Bend the tension strap.
• Insert the tension strap into part (1) of the ratchet clasp (see Fig. 6.39 b).
• Tighten the tension strap.
• Insert the long end of the tension strap into its clamps and the metal spring (see Fig. 6.40). Place the tension strap
around the pipe.
• Position the ratchet clasp, the tension strap clamps and the metal spring on the pipe:
– On a horizontal pipe, mount the tension strap clamps laterally to the pipe, if possible.
– Mount the metal spring opposite the ratchet clasp.
• Make sure that the 2 tension strap clamps are as exactly as possible opposite each other. To do this, check whether the
distance between the tension strap clamps is half the pipe circumference.
• Insert the long end of the tension strap into the slot of the clasp screw (see Fig. 6.41).
• Tighten the tension strap.
• Cut off the protruding tension strap (see Fig. 6.41).
• Tighten the screw of the ratchet clasp.
• Repeat the steps for the second tension strap.
Caution!
The edge of the tension strap is very sharp.
Risk of injury!
→ Debur sharp edges.
→ Wear the required personal protective equipment.
→ Observe the applicable rules.
Fig. 6.39: Ratchet clasp with tension strap
Fig. 6.40: Tension strap with metal spring and clamp
1 – metal spring
2 – tension strap clamp
Notice!
In order to release the screw and the tension strap, press the lever down (see Fig. 6.41).
a
b
1
2
1
1
1
2