2-15
Initial Checkout and Field Installation
HAZARDOUS LOCATIONS
The Model 3095FT was designed with an explosion-proof housing and
circuitry suitable for intrinsically safe and non-incendive operation.
Individual transmitters are clearly marked with a tag indicating the
certifications they carry. See Section 7 - Specifications and Reference
Data for specific approval categories, and see Appendices A through D
for approval drawings.
FIELD INSTALLATION
EQUIPMENT
The following equipment and tools are not provided with the Model
3095FT. Be sure to review this list before field installing the
transmitter.
• Installation tools
• Field wire between the power supply and the Model 3095FT
• Barriers or seals required for non-incendive or hazardous
locations
• Conduit
• 2-in. mounting pipe or saddles
• Power supply (unless the Remote Power Supply was ordered)
• 3- or 5-valve manifolds
• Impulse piping
• Tie wraps
• Lock for the remote power supply enclosure.
Inductive-based transient protectors, including the
Rosemount Model 470, can adversely affect the output of
the Model 3095FT. Do not use the Model 470 for transient
protection with the Model 3095FT. If transient protection is
desired, install the Transient Protection Terminal Block as
explained on Page 3-5.
Summary of Contents for 3095FT
Page 1: ...R Model 3095FT HART Flow Transmitter 00809 0100 4015 English Rev B1...
Page 2: ......
Page 4: ......
Page 98: ...Rosemount Model 3095FT HART Flow Transmitter 4 50...
Page 117: ...5 19 Troubleshooting and Maintenance FIGURE 5 2 Replacing the Remote Power Supply Battery...
Page 118: ...Rosemount Model 3095FT HART Flow Transmitter 5 20...
Page 146: ...Rosemount Model 3095FT HART Flow Transmitter 7 24...
Page 148: ...Rosemount Model 3095FT HART Flow Transmitter A 2...
Page 149: ...A 3 Appendix A...
Page 150: ...Rosemount Model 3095FT HART Flow Transmitter A 4...
Page 152: ...Rosemount Model 3095FT HART Flow Transmitter B 2...
Page 153: ...B 3 Appendix B...
Page 154: ...Rosemount Model 3095FT HART Flow Transmitter B 4...
Page 155: ...B 5 Appendix B...
Page 156: ...Rosemount Model 3095FT HART Flow Transmitter B 6...
Page 157: ...B 7 Appendix B...
Page 158: ...Rosemount Model 3095FT HART Flow Transmitter B 8...
Page 160: ...Rosemount Model 3095FT HART Flow Transmitter C 2...
Page 161: ...C 3 Appendix C...
Page 162: ...Rosemount Model 3095FT HART Flow Transmitter C 4...
Page 164: ...Rosemount Model 3095FT HART Flow Transmitter D 2...
Page 165: ...D 3 Appendix D...
Page 166: ...Rosemount Model 3095FT HART Flow Transmitter D 4...
Page 167: ...D 5 Appendix D...
Page 168: ...Rosemount Model 3095FT HART Flow Transmitter D 6...
Page 183: ......