![Fisher-Rosemount 3095FT Manual Download Page 140](http://html1.mh-extra.com/html/fisher-rosemount/3095ft/3095ft_manual_2300591140.webp)
Rosemount Model 3095FT HART Flow Transmitter
7-18
Item
No.
DRAIN/VENT VALVE KITS
Part Description
Part Number
Price
Each
Spares
(1)
Category
10
Vent Valve Kits
316L SST Valve Stem and Seat Kit
Hastelloy C Valve Stem and Seat Kit
(Each kit contains parts for one transmitter.)
01151-0028-0022
01151-0028-0023
•
•
A
Item
No.
O-RING PACKAGES
Part Description
Part Number
Price
Each
Spares
(1)
Category
2
8
15
14
Electronic Housing, Cover (Standard and Meter)
Electronics Housing, Module
Process Flange, Glass-filled
Teflon
®
Flange Adapter, Glass-filled
Teflon
(Each package contains 12 O-rings.)
03031-0232-0001
03031-0233-0001
03031-0234-0001
03031-0242-0001
•
•
•
•
B
B
B
B
Item
No.
MOUNTING BRACKETS
Part Description
Part Number
Price
Each
Spares
(1)
Category
Coplanar Flange Bracket Kits (Figure 7-3)
SST Bracket, 2-in. Pipe or Panel Mount, SST Bolts
03031-0189-0003
•
B
Item
No.
BOLT KITS
Part Description
Part Number
Price
Each
Spares
(1)
Category
30
31
32
Coplanar Flange (Figure 7-8)
Flange Bolt Kit
Carbon Steel (set of 4)
316 SST (set of 4)
Flange/Adapter Bolt Kit
Carbon Steel (set of 4)
316 SST (set of 4)
Manifold/Flange Kit
Carbon Steel (set of 4)
316 SST (set of 4)
(Each kit contains bolts for 1 transmitter)
03031-0312-0001
03031-0312-0002
03031-0306-0001
03031-0306-0002
03031-0311-0001
03031-0311-0002
•
•
•
•
•
•
B
Manifold
Carbon Steel
316 SST
Use Bolts Supplied with
Anderson Greenwood Manifold
Item
No.
LCD METER OPTION
Part Description
Part Number
Price
Each
Spares
(1)
Category
17
33
18
17
33
Aluminum Housing (Figure 7-5)
Meter Kit
Meter Display
6-pin Interconnection Header
Cover Assembly
Meter
Meter Display
6-pin Interconnection Header
Cover Assembly Kit
03095-0392-0001
03095-0392-0002
03095-0392-0003
•
•
•
A
A
Summary of Contents for 3095FT
Page 1: ...R Model 3095FT HART Flow Transmitter 00809 0100 4015 English Rev B1...
Page 2: ......
Page 4: ......
Page 98: ...Rosemount Model 3095FT HART Flow Transmitter 4 50...
Page 117: ...5 19 Troubleshooting and Maintenance FIGURE 5 2 Replacing the Remote Power Supply Battery...
Page 118: ...Rosemount Model 3095FT HART Flow Transmitter 5 20...
Page 146: ...Rosemount Model 3095FT HART Flow Transmitter 7 24...
Page 148: ...Rosemount Model 3095FT HART Flow Transmitter A 2...
Page 149: ...A 3 Appendix A...
Page 150: ...Rosemount Model 3095FT HART Flow Transmitter A 4...
Page 152: ...Rosemount Model 3095FT HART Flow Transmitter B 2...
Page 153: ...B 3 Appendix B...
Page 154: ...Rosemount Model 3095FT HART Flow Transmitter B 4...
Page 155: ...B 5 Appendix B...
Page 156: ...Rosemount Model 3095FT HART Flow Transmitter B 6...
Page 157: ...B 7 Appendix B...
Page 158: ...Rosemount Model 3095FT HART Flow Transmitter B 8...
Page 160: ...Rosemount Model 3095FT HART Flow Transmitter C 2...
Page 161: ...C 3 Appendix C...
Page 162: ...Rosemount Model 3095FT HART Flow Transmitter C 4...
Page 164: ...Rosemount Model 3095FT HART Flow Transmitter D 2...
Page 165: ...D 3 Appendix D...
Page 166: ...Rosemount Model 3095FT HART Flow Transmitter D 4...
Page 167: ...D 5 Appendix D...
Page 168: ...Rosemount Model 3095FT HART Flow Transmitter D 6...
Page 183: ......