48
www.fi-measurement.com
automatically.
6
F
a.
Relay 3 (SP2) starts action.
b.
Slow dispensing starts.
7
G
a.
Weight value of SP2 is reached.
b.
Relay 3 stops action.
c.
Slow dispensing stops.
8
G
H
a.
Time delay as set forth in Delay 3. This is the
stabilization / waiting time before the dispensing
process is completed and automatically stopped.
b.
If a weight value
less
than SP2 is detected in this
period, Seq.
6
and
7
will be repeated
automatically.
Notes: -
If any weight (e.g. a value = point
ERR
) >= SP3 is
detected in this period: -
•
Relay 4 (error) will be triggered.
•
Dispensing sequence come to a halt.
•
Manual intervention is required set.
9
H
a.
Instrument displays
Stop
.
b.
Dispensing sequence completed.
c.
Instrument displays gross weight (Tare weight +
weight of material filled).
d.
A printout
40
41
is generated automatically.
e.
A signal is sent to trigger Relay1.
40
Number of printout copy depends on F18 Mode 3.
41
Whether the current transaction will be automatically accumulated to memory depends on F17
setting.
Summary of Contents for AFM18
Page 2: ...1 www fi measurement com ...
Page 12: ...11 www fi measurement com 3 2 Connection Points AFM18 FM18 FM18S ...
Page 20: ...19 www fi measurement com 5 4 Internal Function Table ...
Page 21: ...20 www fi measurement com ...
Page 22: ...21 www fi measurement com ...
Page 23: ...22 www fi measurement com ...
Page 24: ...23 www fi measurement com ...
Page 25: ...24 www fi measurement com ...