6.14 Constant Feeding (F25 = Mode 3) & Dispensing (F25 = Mode 4)
Modes
Constant feeding and dispensing control logics are built-in the software to
support constant feeding and dispensing system.
-
To utilize constant feeding function, select Mode 3 in internal function F25.
-
To utilize constant dispensing function, select Mode 4 in internal function
F25.
Refer to: -
•
6.15.1 for constant feeding mode illustration system block diagram.
•
6.16.1 for constant dispensing mode illustration system block diagram.
6.14.1 Control Parameters
Control parameters are available to achieve various feeding / dispensing
applications and target, Refer below table for more details.
Parameter
Description
Tare H
For Mode 3 only.
•
The highest weight value of an empty container which
can be automatically tare off.
•
Condition: Tare H > = Tare L.
•
To disable Tare H checking, input 000000.
Tare L
For Mode 3 only.
•
This is the lowest weight value of a empty container
which can be automatically tare off.
•
Condition: Tare L < =Tare H.
•
To disable Tare L checking, input 000000.
rEF H
(Refill Hi)
For Mode 4 only
•
This is the weight value of the reservoir at or above
which auto refill stops.
•
Condition: H > = rEF L > = SP2 > = SP1 (SP3 is not
considered).
rEF L
(Refill Lo)
For Mode 4 only.
•
This is the weight value of the reservoir at or below
Summary of Contents for AFM18
Page 2: ...1 www fi measurement com ...
Page 12: ...11 www fi measurement com 3 2 Connection Points AFM18 FM18 FM18S ...
Page 20: ...19 www fi measurement com 5 4 Internal Function Table ...
Page 21: ...20 www fi measurement com ...
Page 22: ...21 www fi measurement com ...
Page 23: ...22 www fi measurement com ...
Page 24: ...23 www fi measurement com ...
Page 25: ...24 www fi measurement com ...