![Fidelity Measurement AFM18 Operation Manual Download Page 40](http://html.mh-extra.com/html/fidelity-measurement/afm18/afm18_operation-manual_2287074040.webp)
39
www.fi-measurement.com
which auto refill starts.
•
Condition: rEFl L < = rEF H
SP1
(Set Point 1)
•
Set Point 1.
•
This is the weight value at or above which fast
feeding/dispensing comes to end.
•
Condition: SP1 < = SP2.
SP2
(Set Point 2)
Set Point 2.
It is usually used for slow feeding / dispensing comes to
end.
•
This is the weight value at or above which slow
feeding/dispensing comes to end.
•
Condition: SP1 < = SP2 < = SP3.
SP3
(Set Point 3)
Set Point 3.
It is usually used as alarm when the preset value is
reached / exceeded.
•
This is the weight value at or above which (if such
weight value is achieved within the time delay
duration set in Delay 3) Relay 4 starts action.
•
Condition: SP1 <= SP2 <= SP3.
dELAy1
(Delay Time 1)
Time duration (00 ~ 99 sec). This is the time duration in
between: -
•
When [FUNC] key (Start) key is pressed, and
•
SP1 (Relay 2) starts action.
dELAy2
(Delay Time 2)
Time duration (00 ~ 99 sec) This is the time duration in
between: -
•
When weight value of SP1 is reached or exceeded
(Relay 2 stops action), and
•
SP2 (Relay 3) starts action.
dELAy3
(Delay Time 3)
Time duration (00 ~ 99 sec). This is the time duration in
between: -
•
(Normal case) When weight value of SP2 is reached
or exceeded (Relay 3 stops action) and before
feeding / dispensing sequence stops, or
•
(Alarm case) When weight value of SP2 is reached or
exceeded and before weight value set in SP3 is/will
Summary of Contents for AFM18
Page 2: ...1 www fi measurement com ...
Page 12: ...11 www fi measurement com 3 2 Connection Points AFM18 FM18 FM18S ...
Page 20: ...19 www fi measurement com 5 4 Internal Function Table ...
Page 21: ...20 www fi measurement com ...
Page 22: ...21 www fi measurement com ...
Page 23: ...22 www fi measurement com ...
Page 24: ...23 www fi measurement com ...
Page 25: ...24 www fi measurement com ...