Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual
Page 223 of 254
Command
Description
NULL none, for PDP type OSP: IHOSS (Obsolete)
PPP Point-to-point protocol for a PDP such as IP
PAD character stream for X.25 character (triple X PAD) mode (Obsolete)
X25 X.25 L2 (LAPB) for X.25 packet mode (Obsolete).
M-OPT-PPP MS supports manufacturing specific protocol
M-HEX MS supports manufacturing specific protocol
M-RAW_IP MS supports manufacturing specific protocol.
<cid>
A numeric parameter which specifies a particular PDP context definition (see
the +CGDCONT and +CGDSCONT commands).
Example
AT+CGDATA=ppp
CONNECT
…….
……..
AT+CGDATA=?
+CGDATA: (PPP,M-OPT-PPP,M-HEX,M-RAW_IP,PAD,X25)
OK
Reference
3GPP TS 27.007
11.2.16 +CGDSCONT
,
Define Secondary PDP Context
This command is used to define a secondary PDP context by specifying the PDP context parameter
values for a <cid> (local context identification parameter). If the command is used only with the one
parameter <cid>, it means that the corresponding PDP context becomes undefined.
Command
Description
Set
[Function]
Set command specifies PDP context parameter values for a Secondary PDP context
identified by the (local) context identification parameter, <cid>.
[Syntax]
AT+CGDSCONT=[<cid>, <p_cid> [,<d_comp>[,<h_comp>
[,<IM_CN_Signaling_Flag_Ind>]
]]]
[Response/Action]
OK