Reproduction forbidden without Fibocom Wireless Inc. written authorization – All Rights Reserved.
FIBOCOM L860 AT Commands User Manual
Page 178 of 254
Command
Description
CME ERROR: <error>
Read
[Function]
Read command returns the XCESQ command setting, received signal quality
parameters.
[Syntax]
AT+XCESQ?
[Response/Action]
+XCESQ:
<n>,<rxlev>,<ber>,<rscp>,<ecno>,<rsrq>,<rsrp>,<rssnr>,<1xrtt_rssi>,<1xrtt_ecio>,
<evdo_rssi>,<evdo_sinr>
OK
Test
[Function]
Test command returns values supported as compound values.
[Syntax]
AT+XCESQ=?
[Response/Action]
+XCESQ: (list of supported <n>s),(list of supported <rxlev>s),(list of supported
<ber>s),(list of supported <rscp>s),(list of supported <ecno>s),(list of supported
<rsrq>s),(list of supported <rsrp>s),(list of supported <rssnr>s),(list of supported
<1xrtt_rssi>s),(list of supported <1xrtt_ecio>s ),(list of supported <evdo_rssi>s ),(list of
supported <evdo_sinr>s )
OK
Parameters
<n>
0 disable
1 enable
Example
AT+XCESQ=1
OK
AT+XCESQ?
+XCESQ: 1,99,99,255,255,1,37,-18,255,255,255,255
OK
AT+XCESQ=?
+XCESQ: