TROUBLESHOOTING
CONTAINER WON’T LIFT
POSSIBLE CAUSE
REMEDY
Insufficient hydraulic pressure.
Cable broken.
Cable loose from the lifting device (drum/cylinder).
Container overload.
Container frozen to the ground.
Linkage binding or restrictive.
Lifting motor or cylinder(s) by-passing hydraulic
fluid.
Shear pin or key broken between winch shaft and
drum.
Check pressures as described in Sec. 7, Check-
Out.
Replace cable.
Secure cable to lifting device.
Reduce weight of material in container.
Do not use lifting device to break container loose
from the ground.
Repair or replace linkage as required.
Repair or replace the defective component.
Replace the key or pin.
1.
2.
3.
4.
5.
6.
7.
8.
1.
2.
3.
4.
5.
6.
7.
8.
WINCH MOTOR LEAKING
POSSIBLE CAUSE
REMEDY
Shaft seal damaged.
Motor worn internally.
Replace shaft seal.
Replace motor.
1.
2.
1.
2.
CONTAINER RAISES VERY SLOWLY
POSSIBLE CAUSE
REMEDY
Winch motor by-passing.
Rear loader hydraulic system not providing suffi-
cient flow rate or pressure for container handling
systems.
Repair or replace motor.
Check and repair rear loader hydraulic system fol-
lowing procedures in Service manual.
1.
2.
1.
2.
Summary of Contents for LEACH 2R-III
Page 2: ......
Page 8: ......
Page 26: ...SECTION 2 2 8 ...
Page 28: ...OPERATION SECTION 3 LOCATION OF OPERATING CONTROLS 3 2 4 6 5 7 8 1 2 3 8 9 10 11 12 7 ...
Page 46: ...SECTION 3 3 20 ...
Page 54: ...SECTION 4 4 8 ...
Page 60: ...SECTION 6 6 4 PREVENTIVE MAINTENANCE 1 2 3 4 5 6 7 8 ...
Page 62: ...SECTION 6 6 6 ...
Page 76: ...SECTION 7 7 10 ...