CHECK-OUT
CHECK PACK CYCLE TIME
OPERATIONAL STATUS
Truck Running
PTO Engaged
Speed Up On
Activate both the packer panel lever and carrier
panel lever. Using a stopwatch, time a complete
cycle. A complete cycle should take 23 to 26 sec-
onds.
1.
IF NOT:
The engine ECU (Electronic Control Unit) may have
to be programmed by an authorized chassis dealer.
2.
NOTE:
It is important the cycle time is correct before perform-
ing the following pressure checks.
CHECK PRESSURES
The pressure checks provided below will indicate the
operating condition of the hydraulic system. Detailed
adjustment procedures are provided later in this sec-
tion and are referenced at the appropriate check-out
procedure. Prior to performing pressure checks:
OPERATIONAL STATUS
Truck Off
PTO Disengaged
Install a gauge capable of reading at least 3000
PSI (207 BAR) on the test coupling.
Start the unit, engage PTO/PUMP and turn speed
up switch on.
1.
2.
PACKER
LEVER
CARRIER
LEVER
0
30
15
45
TEST
COUPLING