![background image](http://html.mh-extra.com/html/federal-signal-corporation/leach-2r-iii/leach-2r-iii_service-manual_548517058.webp)
SECTION 6
6-2
PREVENTIVE MAINTENANCE
LUBRICATION CHART
INSTRUCTIONS
Grease weekly (every 40 hrs. of operation) with
MOBILUX EPI-SERVICE grease or equivalent.
Oil weekly (every 40 hrs. of operation) with SAE # 10
or equivalent.
ILLUS. # LUBE POINT
QTY
NOTE
1
Control levers
2
1
2
PTO shaft
2
3
Tailgate lift cylinder 4
(top and bottom)
4
Tailgate clamps
2
5
Operating cylinders 4
2
top pivots
Not Shown Telescopic cylinder
2
pivot pins
ILLUS # LUBE POINT
QTY
NOTE
NOTE
The packer panel must be in the home position to
lubricate the following lube points.
6
Operating valve
4
1
control lever
7
Inside & outside
3
bearing housing
8
Carrier panel cylinder 1
end
9
Packer panel cylinder 2
rod ends
10
Rollers
4
3 & 4
11
Optional control
2
lever(s)
In below freezing climates all grease and fluids
should have a cold test rating of at least -20 F.