SPECIFICATIONS
LUBRICANTS
Oil...........................SAE # 10 or equivalent
Grease....................Multiservice (quality grade)
HYDRAULIC SYSTEM
CAPACITY (approximately):
Fluid tank........................................................................................................................................50 gallons
Total system
System pressure settings...............................................................................................................2350 PSI (162 BAR)
Type of fittings.................................................................Steel tubing with brazed ORFS fittings: reinforced rubber
hose with crimped full-flow ORFS fittings, o-ring fittings
Filtration..................................................................................................................Suction: Reusable wire mesh type
Return line: Disposable filter element located on return line to the tank
PUMP
Type...................................................................................................................Positive displacement; gear type driven
by the PTO from the truck transmission, or by the engine
Capacity......................................................................................................................................42 GPM @ 1200 RPM
LEACH HYDRAULIC FLUID RECOMMENDATION
All Leach hydraulic systems are factory filled with a high quality anti-wear htdraulic fluid meeting an ISO 32
specification. On units put into service where there are high ambient temperatures or sustained high duty cycles,
it may be desirable to change the fluid to an ISO 46 specification (higher viscosity). In colder climates or light duty,
an ISO 22 might be more appropriate. The International Standards Orginization assigns specification numbers so
that a consumer receives the same product from various suppliers.
GRADE ISO/VISCOSITY................................................ 22
32
46
AGMA NO........................................................................
_
_
1
Gravity API......................................................................
33
31
31
Flash, Degree F..............................................................
375
380
390
Pour Point......................................................................
-20
-20
-20
Viscosity:
SSU @ 100 Degrees F...........................................
112
158
228
SSU @ 210 Degrees F...........................................
40
44
48
cSt @ 40 Degrees C..............................................
21
30.5
44
cSt @ 100 Degrees C............................................
4.1
5.2
6.5
Viscosity Index...............................................................
98
99
99
ASTM Oxidation Test (Hours to 2.0 Neut. No.) ........ 2500 2500
2500
ASTM Rust Test, A & B..................................................
Pass Pass
Pass
Foam Test.......................................................................
Pass Pass
Pass
Vickers Vane Pump Test................................................
Pass Pass
Pass
Dielectric Strength (ASTM 877) EC # @ 180 Degrees F. 25Kv
25Kv
25Kv
40-37-3 (10) 40-37-3 (15) 40-37-3 (15)
Do not use engine oil, automatic transmission fluid (ATF) or add diesel
fuel or kerosene to the hydraulic fluid. Service life of all hydraulic system
components may be adversely affected.
HYDRAULIC FLUID
To serve its purpose and give long and satisfactory service, hydraulic fluid must possess desirable physical and
chemical characteristics. Stability over a wide range of trmperatures and under agitation is very important.
Premium hydraulic fluids should be used in Leach hydraulic systems. In addition to the above characteristics
selected additives should be incorporated to provide additional resistance to wear, corrosion, oxidation, decom-
position and foaming. All additive blending should be done by the lubricant supplier so that they are compatible
with each other.
A reputable lubricant supplier backed by a reputable oil company is great assurance of obtaining high quality
products and generally speaking, higher quality is worth the higher initial cost.
Summary of Contents for LEACH 2R-III
Page 2: ......
Page 8: ......
Page 26: ...SECTION 2 2 8 ...
Page 28: ...OPERATION SECTION 3 LOCATION OF OPERATING CONTROLS 3 2 4 6 5 7 8 1 2 3 8 9 10 11 12 7 ...
Page 46: ...SECTION 3 3 20 ...
Page 54: ...SECTION 4 4 8 ...
Page 60: ...SECTION 6 6 4 PREVENTIVE MAINTENANCE 1 2 3 4 5 6 7 8 ...
Page 62: ...SECTION 6 6 6 ...
Page 76: ...SECTION 7 7 10 ...