5-5
(E code continued)
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer to
page:
E98
Terminal [FWD] Function
-
-
N
Y
98
E99
Terminal [REV] Function
0
(1000): Select multi-frequency
(
SS1
)
-
-
N
Y
99
1
(1001): Select multi-frequency
(
SS2
)
2
(1002): Select multi-frequency
(
SS4
)
3
(1003): Select multi-frequency
(
SS8
)
4
(1004): Select ACC/DEC time
(
RT1
)
6
(1006): Enable 3-wire operation
(
HLD
)
7
(1007): Coast to a stop
(
BX
)
8
(1008): Reset alarm
(
RST
)
9
(1009): Enable external alarm trip
(
THR
)
10
(1010): Ready for jogging
(
JOG
)
11
(1011): Select frequency command 2/1
(
Hz2/Hz1
)
12
(1012): Select motor 2/motor 1
(
M2/M1
)
13
: Enable DC braking
(
DCBRK
)
14
(1014): Select torque limiter level
(
TL2/TL1
)
17
(1017):
(
UP
)
18
(1018):
(
DOWN
)
19
(1019):
(
WE-KP
)
20
(1020): Cancel PID control
(
Hz/PID
)
21
(1021):
(
IVS
)
(
LE
)
25
(1025): Universal DI
(
U-DI
)
26
(1026):
(
STM
)
30
(1030): Force to stop
(
STOP
)
33
(1033):
(
PID-RST
)
34
(1034): Hold PID integral component
(
PID-HLD
)
42
(1042): Reserved *2
43
(1043): Reserved *2
44
(1044): Reserved *2
45
(1045): Reserved *2
98
: Run forward
(
FWD
)
99
: Run reverse
(
REV
)
5-35
24
(1024):
UP (Increase output frequency)
DOWN (Decrease output
frequency)
Enable data change with keypad
Switch normal/inverse operation
Enable auto search for idling motor
speed at starting
Reset PID integral and differential
components
Data setting range
Name
Note: In the case of
THR
and
STOP
, data (1009) and (1030) are for normal
logic, and "9" and "30" are for negative logic, respectively.
Setting the value of 1000s in parentheses ( ) shown above assigns a
negative logic input to a terminal.
Enable communications link via
RS-485 or field bus
Selecting function code data assigns the corresponding function to
terminals [FWD] and [REV] as listed below.
C codes: Control Functions
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer to
page:
C01
Jump Frequency 1
0.0 to 400.0
0.1
Hz
Y
Y
0.00
-
C02
2
Y
Y
0.00
C03
3
Y
Y
0.00
C04
(Hysteresis width) 0.0 to 30.0
0.1
Hz
Y
Y
3.0
C05
Multi-Frequency 1
0.00 to 400.0
0.01
Hz
Y
Y
0.00
C06
2
Y
Y
0.00
C07
3
Y
Y
0.00
C08
4
Y
Y
0.00
C09
5
Y
Y
0.00
C10
6
Y
Y
0.00
C11
7
Y
Y
0.00
C12
8
Y
Y
0.00
C13
9
Y
Y
0.00
C14
10
Y
Y
0.00
C15
11
Y
Y
0.00
C16
12
Y
Y
0.00
C17
13
Y
Y
0.00
C18
14
Y
Y
0.00
C19
15
Y
Y
0.00
C20
Jogging Frequency
0.00 to 400.0
0.01
Hz
Y
Y
0.00
C21
T imer Operation
0: Disable
-
-
N
Y
0
5-50
1: Enable
C30
Frequency Command 2
0: UP/DOWN keys on keypad
-
-
N
Y
2
5-13
1: Voltage input to terminal [12]
(-10 to +10 VDC)
2: Current input to terminal [C1]
(C1 function) (4 to 20 mA DC)
3:
5: Voltage input to terminal [C1]
(V2 function) (0 to 10 VDC)
7: T erminal command
UP
/
DOWN
control
11: DIO interface card (option)
12: PG interface card (option)
Sum of voltage and current inputs to terminals [12] and
[C1] (C1 function)
Data setting range
Name
*
2
These function codes and their data are displayed, but they are reserved for particular manufacturers. Unless otherwise
specified, do not access these function codes.
Summary of Contents for FRENIC-Multi series
Page 194: ...MEMO MEMO...