![FE FRENIC-Mini Instruction Manual Download Page 89](http://html.mh-extra.com/html/fe/frenic-mini/frenic-mini_instruction-manual_547580089.webp)
5-12
(P codes continued)
Code Name
Data
setting
range
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
P63
Permanent magnet
synchronous motor *1
(Induced voltage)
0 (Disable PMSM),
80 to 240 (for 200 V class series)
160 to 500 (for 400 V class series)
1 V
N Y2 0 –
P74
(Reference current at
starting)
10 to 200
1
%
Y
Y1
Y2
80
P89
(Control switching level) 10 to 100
1
%
Y
Y1
Y2
10
P90
(Overcurrent protection
level)
0.00 (Disable),
0.01 to 100.0
0.01
A
Y
Y1
Y2
0.00
P91 (d-axis compensation gain
under damping control)
0.0 to 25.0, 999 (Table value)
0.1
–
Y
Y1
Y2
999
P92
(q-axis compensation
gain under damping
control)
0.0 to 25.0, 999 (Table value)
0.1
–
Y
Y1
Y2
999
P93
(Step-out detection
current level)
0.0 to 100, 999 (Table value)
1
%
Y
Y1
Y2
999
P99
Motor 1 Selection
0: Motor characteristics 0 (Fuji standard IM,
8-series)
–
–
N 0
5-63
1: Motor characteristics 1 (HP rating IM)
3: Motor characteristics 3 (Fuji standard IM,
6-series)
4:
Other
motors
(IM)
20:
Other
motors
(PMSM)
21: Fuji standard PMSM without sensor
Y1
Y2
*1 The PMSM drive is available in the ROM version 0500 or later.