![FE FRENIC-Mini Instruction Manual Download Page 88](http://html.mh-extra.com/html/fe/frenic-mini/frenic-mini_instruction-manual_547580088.webp)
5-11
(C codes continued)
Code Name
Data
setting
range
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
C94
Jump Frequency 4 *1
0.0 to 400.0
0.1
Hz
Y
Y
0.0
–
C95
5
Y Y 0.0
C96
6
Y Y 0.0
C99
Digital Reference
Frequency *1
0.00 to 400.00
0.01
Hz
–
Y
0.00
P codes: Motor 1 Parameters
Code Name
Data
setting
range
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
P02 Motor
1
(Rated capacity)
0.01 to 30.00
(kW when P99 = 0, 3, 4, 20 or 21)
0.01 to 30.00 (HP when P99 = 1)
0.01
0.01
kW
HP
N
Y1
Y2
See
Table A.
5-61
P03
(Rated current) 0.00 to 100.0
0.01
A
N
Y1
Y2
Rated
value of
Fuji
standard
motor
P04 (Auto-tuning)
0:
Disable
–
–
N N 0
1: Tune when the motor stops (%R1, %X)
2: Tune when the motor is rotating under V/f
control (%R1, %X, no-load current, slip
frequency).
P06
(No-load current) 0.00 to 50.00
0.01
A
N
Y1
Y2
P07 (%R1)
0.00
to
50.00
0.01
%
Y
Y1
Y2
P08 (%X)
0.00
to
50.00
0.01
%
Y
Y1
Y2
Rated
value of
Fuji
standard
motor
P09
(Slip compensation gain
for driving)
0.0 to 200.0
0.1
%
Y*
Y
100.0
5-62
P10
(Slip compensation
response time)
0.01 to 10.00
0.01
s
Y
Y1
Y2
1.00
P11
(Slip compensation gain
for braking)
0.0 to 200.0
0.1
%
Y*
Y
100.0
P12
(Rated slip frequency) 0.00 to 15.00
0.01
Hz
N
Y1
Y2
Rated
value of
Fuji
standard
motor
5-61
P60
Permanent magnet
synchronous motor *1
(Armature resistance)
0.00 (Disable PMSM),
0.01 to 50.00
0.01
Ω
Y
Y1
Y2
0.00
–
P61 (d-axis
inductance)
0.00 (Disable high-efficiency control),
0.01 to 500.0
0.01
mH
Y
Y1
Y2
0.00
P62 (q-axis
inductance)
0.00 (Disable PMSM),
0.01 to 500.0
0.01
mH
Y
Y1
Y2
0.00
*1 The PMSM drive is available in the ROM version 0500 or later.