3-9
Figure 3.3 illustrates the menu transition in Programming mode.
* Displayed only when a remote keypad (option) is set up for use.
Figure 3.3 Menu Transition in Programming Mode
Limiting menus to be displayed
The menu-driven system has a limiter function (specified by function code E52) that limits menus to
be displayed for the purpose of simple operation. The factory default is to display Menu #1 "Data
setting" only, allowing no switching to any other menu.
Table 3.6 Function Code E52 – Keypad (Mode Selection)
Function code data (E52)
Menus selectable
0: Function code data editing mode
Menu #1 "Data setting" (factory default)
1: Function code data check mode
Menu #2 "Data checking"
2: Full-menu mode
Menu #1 through #6
Note: Menu #7 appears only when the remote keypad (option) is connected.