Section 7 - System Programming
7–11
Unless otherwise specified, the trigger output is normally floating, and sinks on activation.
QUESTION 08
AC SOUNDER, ARM WHILE FAULTED
DEFAULT = 0000
Question 08, L1
AC SOUNDER ENABLE - Selecting this option will cause the keypad sounder to pulse after
fifteen minutes of no AC. Entering a valid User Code will turn the sounder off.
ARM WHILE FAULTED – Selecting this option will allow the user to arm the system with
any delay or interior type zone still faulted.
Digit
AC SOUNDER
ARM WHILE
FAULTED
0
NONE
NONE
1
9
2
9
3
9
9
Question 08, L2 - Future
Question 08, L3 – Future
Question 08. L4 - Future
QUESTION 09
ACCOUNT NUMBER 1
DEFAULT = 1234
Enter the 3- or 4-digit subscriber account number for central station phone number 1 in
locations L1-L4. If a 3-digit number is used, enter an “A” in location L4. Valid entries are 0-9,
and B-F. The value “A” is interpreted as the null value for account numbers.
QUESTION 10
ACCOUNT NUMBER 2
DEFAULT = AAAA
Enter the 3- or 4-digit subscriber account number for the central station phone number 2 in
locations L1-L4. If a 3-digit number is used, enter an “A” in location L4. Valid entries are 0-9,
and B-F. The value “A” is interpreted as the null value for account numbers. If the second
phone number is not used, this question can be left as factory-defaulted.
This account number must be entered if a second receiver phone number has been
entered for backup or split reporting.
Zone Programming
Questions 11-14 represent all the options related to programmable zones 1-4. Each question
contains four locations, L1-L4. The first two locations (L1 and L2) define the zone type and
options. The second two locations (L3 and L4) define the Alarm Code transmitted to the
central station for that zone.
Zone Types
Zones 1-4 can be programmed for any one of the following zone types:
Summary of Contents for XL-1T
Page 2: ...ii ...
Page 10: ...XL 1T Installation and Setup Guide 1 2 ...
Page 26: ...XL 1T Installation and Setup Guide 4 4 ...
Page 32: ...XL 1T Installation and Setup Guide 5 6 ...
Page 36: ...XL 1T Installation and Setup Guide 6 4 ...
Page 58: ...XL 1T Installation and Setup Guide 8 4 ...
Page 60: ...XL 1T Installation and Setup Guide 9 2 ...
Page 66: ...XL 1T Installation and Setup Guide B 2 ...
Page 72: ... 1 6l N9883 09 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset NY 11791 ...