4–1
S E C T I O N 4
Keypad Layout
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Figure 4-1: Layout of XK-104 and 6805 Keypads
Layout of Keypads
1. ZONE STATUS LEDs
These LEDs display the current zone status including alarms, bypasses, troubles, and
faults. Each condition will cause these LEDs to operate differently:
Alarms
Fast blink (approx. 150mS ON - 150mS OFF).
Troubles
Slow pulse (approx. 600mS ON - 600mS OFF).
Bypasses
Wink (100mS ON - 900mS OFF). Zone bypasses are displayed as
a very slow wink of the zone LED light.
Faulted Zones
Solid ON. Faulted zones are the lowest-priority indication.
Faulted burglary zones are displayed with the LED solidly ON
while the system is disarmed.
Normal
OFF.
Upon Entry to disarm the system, the keypad sounder will annunciate to warn the user to disarm it.
In addition, the respective zone LED(s) will be ON to indicate zones THAT are violated (e.G., entry
door and motion detector).
2. ARM/DISARM LED
This LED indicates whether the system is currently armed (ON) or disarmed (OFF).
Fast blink
Alarm Mode
Slow Wink
Fail to communicate with central station
6805 KEYPAD
STAY
3
2
1
4
5
6
7
8
9
*
#
0
BYPASS
INSTANT
CODE
7
8
9
10
.
5
2
SYSTEM READY
11
ARM
AC/LB
READY
1
2
3
4
XK-104 KEYPAD
COVER
OPEN
Stay
Instant
Bypass
Code
*
0
#
7
8
9
4
5
6
1
2
3
P
A
F
2
3
6
1
7
9
10
8
12
INSTANT
STAY
4
5
Summary of Contents for XL-1T
Page 2: ...ii ...
Page 10: ...XL 1T Installation and Setup Guide 1 2 ...
Page 26: ...XL 1T Installation and Setup Guide 4 4 ...
Page 32: ...XL 1T Installation and Setup Guide 5 6 ...
Page 36: ...XL 1T Installation and Setup Guide 6 4 ...
Page 58: ...XL 1T Installation and Setup Guide 8 4 ...
Page 60: ...XL 1T Installation and Setup Guide 9 2 ...
Page 66: ...XL 1T Installation and Setup Guide B 2 ...
Page 72: ... 1 6l N9883 09 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset NY 11791 ...