7–8
Digit
ENTRY TIMEOUTS
0
1 SECOND
1
5 SECONDS
2
10 SECONDS
3
15 SECONDS
4
20 SECONDS
5
25 SECONDS
6
30 SECONDS
7
35 SECONDS
8
40 SECONDS
9
45 SECONDS
A
50 SECONDS
B
55 SECONDS
C
1 MINUTE
D
1 MINUTE 5 SECONDS
E
1 MINUTE 10 SECONDS
F
3 MINUTES
Question 06, L2
Exit Delay
Default = 6
Enter the desired exit delay time.
For UL applications, the maximum exit delay shall not exceed 60 seconds.
Digit
EXIT TIMEOUTS
0
1 SECOND
1
10 SECONDS
2
20 SECONDS
3
30 SECONDS
4
40 SECONDS
5
50 SECONDS
6
1 MINUTE
7
1 MINUTE 10 SECONDS
8
1 MINUTE 20 SECONDS
9
1 MINUTE 30 SECONDS
A
1 MINUTE 40 SECONDS
B
1 MINUTE 50 SECONDS
C
2 MINUTES
D
2 MINUTES 10 SECONDS
E
2 MINUTES 20 SECONDS
F
3 MINUTES
Question 06, L3
Burglary Bell Cutoff
Default = 5
Enter the desired bell cutoff time on alarm conditions for Burglary and Panic in 3-minute
intervals. The valid range of input is 1 - F, with F indicating an infinite burglary bell cutoff
(e.g., 3 = 9 minutes). For UL installations in commercial applications, the minimum bell
cutoff is 15 minutes, or six minutes for household burglary applications.
Summary of Contents for XL-1T
Page 2: ...ii ...
Page 10: ...XL 1T Installation and Setup Guide 1 2 ...
Page 26: ...XL 1T Installation and Setup Guide 4 4 ...
Page 32: ...XL 1T Installation and Setup Guide 5 6 ...
Page 36: ...XL 1T Installation and Setup Guide 6 4 ...
Page 58: ...XL 1T Installation and Setup Guide 8 4 ...
Page 60: ...XL 1T Installation and Setup Guide 9 2 ...
Page 66: ...XL 1T Installation and Setup Guide B 2 ...
Page 72: ... 1 6l N9883 09 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset NY 11791 ...