Section 2 - System Wiring and Hookup
3–7
GROUND START:
Ground start capability can be added to the system through the addition
of the FBII Model 117 module. Consult the 117 Installation Instructions
for hookup information. With this device, some systems can obtain dial
tone where it is not available. At the moment telephone line seizure
occurs, the Telco Tip is momentarily connected to the earth ground to
access dial tone.
The FBII Model 117 module has not been tested for use in UL installations.
P1 Trigger Outputs 1 and 2
The control panel contains two programmable trigger outputs. Trigger #1
terminals are P1-VBELL (+) and P1-T1 (-), and trigger #2 terminals are
P1-VBELL (+) and P1-T2 (-). Refer to programming question #07, location
4 for valid trigger types. By default, trigger #1 is enabled for smoke
detector power obtainable from terminals 12(+) and 13(-). Trigger
#2 cannot be selected for smoke power.
In order to connect devices to the triggers, use connector XL-2GTC (trigger cable). Unless
otherwise specified, the trigger output is normally floating, and actively sinks on activation.
Connect to terminal 12 (+) to obtain a positive reference point. For UL installations, the trigger
outputs are connected to devices rated to operate over the range from 10.1 - 14.0VDC at 50mA.
Auxiliary Device Current Draw Worksheet
DEVICE
CURRENT DRAW
FOR EACH
NUMBER
OF UNITS
TOTAL CURRENT
FOR EACH
XK-104 Keypad
30mA
✴
6805 Keypad
60mA
✴
PIR
✴ ✴
Smoke Detector
✴ ✴
Glassbreak Detector
✴ ✴
✴ ✴
✴ ✴
TOTAL CURRENT FOR ALL DEVICES =
(500mA max.)
✴
Only applies if the device is powered from control terminals
12 (+) and 13 (-).
✴✴
If using devices such as PIRs, smoke detectors, etc., refer to
the specifications for that particular device's current draw. If
the total current draw exceeds 500mA, use an additional
power supply.
Summary of Contents for XL-1T
Page 2: ...ii ...
Page 10: ...XL 1T Installation and Setup Guide 1 2 ...
Page 26: ...XL 1T Installation and Setup Guide 4 4 ...
Page 32: ...XL 1T Installation and Setup Guide 5 6 ...
Page 36: ...XL 1T Installation and Setup Guide 6 4 ...
Page 58: ...XL 1T Installation and Setup Guide 8 4 ...
Page 60: ...XL 1T Installation and Setup Guide 9 2 ...
Page 66: ...XL 1T Installation and Setup Guide B 2 ...
Page 72: ... 1 6l N9883 09 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset NY 11791 ...