XL-1T Installation and Setup Guide
5–2
Instant Arming
TO ARM: Press the INSTANT button followed by a four-digit User Code.
The ARMED and INSTANT LEDs will light on LED-based keypads.
LCD-based keypads will display:
ON: INSTANT
The system is now armed with all programmed delay zones instant; this eliminates the
exit/entry time delays.
INSTANT arming is always enabled (see question #05, location 4).
Stay/Instant Arming
TO ARM: Press the INSTANT button and the STAY button, followed by a valid 4-digit User
Code.
The INSTANT STAY mode will arm the system with the characteristics of both the
INSTANT and STAY modes. The system will be armed with the interior zones bypassed and
the delay zones instant.
LED keypads will have the ARMED, STAY, and INSTANT LEDs lit.
LCD keypads will display:
ON: STAY INSTANT
Disarming
TO DISARM: Press any valid 4-digit User Code, and ARMED LED will extinguish.
If an alarm condition now exists, or if it occurred while the system was armed, the zone
LED(s) and the READY LED will be blinking rapidly. This ALARM MEMORY condition can
be cleared by entering a valid User Code or by pressing the [
✱
] key.
Reset
After an alarm occurs, the system enters alarm memory mode either after bell timeout or
after a user enters a valid User Code silencing the bell and keypad buzzer. Entering a valid
User Code can clear an alarm memory and/or any communication failure. If a fire
alarm occurs, clearing alarm memory will reset the smoke detectors for approximately eight
seconds.
The [
✱
] key can be used as a reset and to clear fire alarms with the entry of a valid
User Code.
The Reset option is always enabled.
Summary of Contents for XL-1T
Page 2: ...ii ...
Page 10: ...XL 1T Installation and Setup Guide 1 2 ...
Page 26: ...XL 1T Installation and Setup Guide 4 4 ...
Page 32: ...XL 1T Installation and Setup Guide 5 6 ...
Page 36: ...XL 1T Installation and Setup Guide 6 4 ...
Page 58: ...XL 1T Installation and Setup Guide 8 4 ...
Page 60: ...XL 1T Installation and Setup Guide 9 2 ...
Page 66: ...XL 1T Installation and Setup Guide B 2 ...
Page 72: ... 1 6l N9883 09 98 Subsidiary of Pittway Corp 149 Eileen Way Syosset NY 11791 ...