7.6.2
Levels of seeds in the hopper
There is a level sensor in the hopper that shows the remaining amount of seeds. The sensor can be adjusted by
height according to the type of seeds or as required by the operator. When the amount drops below the level,
the sensor illuminates a red symbol on the display (top right corner). This signalization is accompanied with a
warning message.
Activation/deactivation of sowing or fertilization – this button is used for activating or deactivating sowing or
fertilization: the button stops the appropriate motor driving the seeding mechanism (also, sensors in the hopper
are deactivated).
Picture 21 – Activation/deactivation of sowing or fertilization
7.7.
SETTING PASSAGE SENSORS
DICKEY JOHN SYSTEM
– The sensitivity setting is fully automated
Activation/deactivation
of sowing or
fertilization
Change of hopper
Signalling low seed level in
the hopper