Enter the weighed
portion here (using the
turning knob)
The speed range of
available for sowing
If the range of speed
is appropriate,
confirm calibration
test
Calibration factor - change from
previous (manual entered or
calculated from previous
calibration)
Procedure – Plug the hole through the stopper, place a bag under the sowing device, which we consider before,
which prevents the seed from falling into the pipeline. After these operations, press the button to start filling the
bag with seed.
Picture 37 – Filing bag
-
The fourth step is to weigh the seed bag and enter the net seed weight into the display unit.
Picture 38 – Entering the weighed value
The whole process will be carried out for the second metering unit as well as for
fertilization
By pressing this key you start
filing the bag with seeds
(hold it until there is a
weighable amount in the
bag)