7.2.
DESCRIPTION OF MACHINE CONTROL BY MÜLLER ELECTRONICS
Falcon sowing machines are equipped with the Müller electronic system. The following chapters briefly
and clearly describe the basic control and description of the electronic system.
7.3.
DESCRIPTION OF THE BASIC DISPLAY
The basic display of the terminal is shown in the picture below the text. The basic display provides access
to all functions that are required for the work in the field. Also, the basic display shows all important data, such
as speed of the machinery, ventilator revolutions, seed quantity, creation of rail lines, and the position of the
rear sowing section.
Picture. 12 – basic display
Hopper level
Fan speed
Travel speed
Trip counting and
tramline marking
Switching
ON/OFF the
application
Seed rate
correction
Machine
hydraulics
control
Settings
Information
Tramline
setting
Sowing
function
Here are visible
activated options,
example markers
Fan speed
Travel speed
Trip couting and
tramline marking
Symbol showing
the position of the
rear sowing
section (recessed)
Engine 1 (
seeder
)
Engine 2 (
seeder
)
Engine 3 (
seeder
)
Summary of Contents for FALCON 3
Page 6: ...Manual FALCON 3 4 6 8 6 99 ...
Page 20: ...Manual FALCON 3 4 6 8 20 99 6 3 HYDRAULIC DIAGRAM OF THE MACHINE ...
Page 77: ...Manual FALCON 3 4 6 8 77 99 ISO alarms ...
Page 78: ...Manual FALCON 3 4 6 8 78 99 Hydraulic alarms Regulation alarms ...
Page 79: ...Manual FALCON 3 4 6 8 79 99 ...
Page 80: ...Manual FALCON 3 4 6 8 80 99 Machine specific alarms ...
Page 81: ...Manual FALCON 3 4 6 8 81 99 ...
Page 82: ...Manual FALCON 3 4 6 8 82 99 ...
Page 83: ...Manual FALCON 3 4 6 8 83 99 ...