XTP CrossPoint Series • HTML Operation
126
Configuration Tab
System Settings Page
The XTP CrossPoint Series matrix switcher downloads the
System Settings
page (see
figure 59) when you click the
Configuration
tab (
1
). The screen consists of fields in
which you can view and edit IP administration and system settings. You can access the
Email Settings
and
Passwords
pages by clicking the appropriate link (see
on page 152 for basic information about IP addresses and subnetting).
192.168.254.254
32
2
2
1
1
3
3
4
4
5
5
6
6
7
7
8
8
9
9
¢
¢
£
£
Figure 59.
System Settings Page
On password-protected connections, there are two levels of protection: administrator and
user. Administrators have full access to all switching capabilities and editing functions. Users
can create ties, create and recall presets, set audio mutes, and view all settings with the
exception of passwords.
IP Settings panel
NOTE:
Editing variables in the
IP Settings
panel can immediately disconnect the
user from the matrix switcher. Extron recommends editing these settings using SIS
commands (see
SIS Command and Response Table for IP- and Remote Port-
, starting on page 119) and protecting the Ethernet access to
this screen by assigning an administrator password to qualified and knowledgeable
personnel only.
The
IP Settings
panel (
2
) provides a location for viewing and editing settings unique to
the Ethernet interface. After editing any of the settings on this page, click the
Submit
button
at the bottom of the page to save the changes.