XTP CrossPoint Series • Programming Guide
92
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Inputs on XTP CP 4i HD 4K PLUS, XTP CP 4i HDMI, XTP CP 4i HDMI DMA, and XTP CP 4i DVI Pro
Boards (continued)
HDCP status
View input HDCP status
E
I
X^
HDCP
}
X1#]
View HDCP status of all inputs
E
IHDCP
}
X1#
1
X1#
2
X1#
3
...
X1#
n
]
Inputs on XTP CP 4i [XTP], XTP CP 4i 4K [XTP], and XTP CP 4i Fiber 4K Boards
Captive screw and Ethernet serial port insertion enables
NOTE:
on page 66 for an overview of using serial port insertions.
Enable an input captive screw serial
port insertion
E
I
X^
*0LRPT
}
LrptI
X^
*0
]
Enable the captive screw serial port
insert on input
X^
. This disables the
Ethernet RS-232 insert.
Enable an input Ethernet serial port
insertion
E
I
X^
*1LRPT
}
LrptI
X^
*1
]
Enable the Ethernet serial port insert
on input
X^
. This disables the captive
screw serial port insert.
Set all RS-232 input insertions
E
I
X1$
*LRPT
}
LrptI00*
X1$]
View input insertion
E
I
X^
LRPT
}
X1$]
View all input insertions
E
ILRPT
}
X1$
1
X1$
2
X1$
3
...
X1$
n
]
One
X1$
for each available (installed)
input, starting at input 1. Inputs that are
not on an XTP CP 4i [XTP], XTP CP 4i
4K [XTP], or XTP CP 4i Fiber 4K board
report as
0
.
Ethernet serial port insert parameters
Set serial port parameters
EX1%
*
X1^
,
X1&
,
X1*
,
X1(
CP
}
Cpn
X1%
•
Ccp
X1^
,
X1&
,
X1*
,
X1(]
Read serial port parameters
EX1%
CP
}
X1^
,
X1&
,
X1*
,
X1(]
Configure current port timeout
E
0*
X2)
TC
}
Pti0*
X2)]
Read current port timeout
E
0TC
}
X2)]
Configure global IP port timeout
E
1*
X2)
TC
}
Pti1*
X2)]
Read global IP port timeout
E
1TC
}
X2)]
Set UART starting point
EX2!
MD
}
Pmd
X2!]
Sets the initial (lowest) port number for
the range of numbers assigned to the
serial port and UARTs.
Read UART starting point
E
MD
}
X2!]
NOTE
:
X^
= Input number (for other than tie)
01
—
16
or
32
X1#
= HDCP status (for inputs)
0
= No source device connected
1
= Source connected is HDCP-compliant
2
= Source connected is not HDCP-compliant
X1$
= Captive screw or UART
0
= Captive screw RS-232 insert (
default
)
1
= Ethernet RS-232 insert (UART)
X1%
= Port number
03
—
18
or
34
= UARTs (inputs) 1 — 16 or 32
X1^
= Baud rate
300
,
600
,
1200
,
1800
,
2400
,
3600
,
4800
,
7200
,
9600
(
default
),
14400
,
19200
,
28800
,
38400
,
57600
,
115200
X1&
= Parity
o
dd,
e
ven,
n
one,
m
ark,
s
pace (only the first letter is required) (
n
= default
)
X1*
= Data bits
7
,
8
(
default
)
X1(
= Stop bits
1
(
default
),
2
X2)
= Port timeout (10-sec. increments)
1
(= 10 seconds) -
65000
(
default is
30
= 300 seconds = 5 minutes
)
X2!
= UART starting point
The starting point (
X2!
) is the rear panel RS-232/RS-422 port.
The next position (
X2!
+1
) is not used.
For the XTP CrossPoint 1600,
X2!
+2
through
X2!
+17
are XTP inputs.
For the XTP CrossPoint 3200,
X2!
+2
through
X2!
+33
are XTP inputs.
Default values
:
1999
= Rear panel remote RS-232/RS-422 port
2000
is unused
2001
through
2016
(
XTP CrossPoint 1600
) = Input 1 through 16
2001
through
2032
(
XTP CrossPoint 3200
) = Input 1 through 32