XTP CrossPoint Series • Programming Guide
116
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Information requests (continued)
Request system status
S
See below
XTP CrossPoint 3200
:
X5!
•
X5!
•
X5!
•
X5!
•
X5!
•
X5@
•
X5#
•
X5#
•
X5#
•
X5#
•
X5#
•
X5#
•
X5#
•
X5$X5$X5$X5$]
XTP CrossPoint 1600
(no redundant power supply):
X5!
•
X5!
•
X5!
•
X5@
•
X5#
•
X5#
•
X5$X5$]
XTP CrossPoint 1600
(redundant power supply):
X5!
•
X5!
•
X5!
•
X5!
•
X5!
•
X5@
•
X5#
•
X5#
•
X5$X5$X5$X5$]
Response description (
XTP CrossPoint 3200
):
PS1 (12 V)
•
PS2 (12 V)
•
PS3 (12 V)
•
PS4 (48 V)
•
3.3 V
•
°F
•
Fan 1 RPM (F1)
•
F2
•
F3
•
F4
•
F5
•
F6
•
F7
•
PS status 1 (PS1) PS2 PS3 PS4
]
Response description (
XTP CrossPoint 1600
,
without
optional redundant power supply):
PS1 (12 V)
•
PS2 (48 V)
•
3.3 V
•
temp. (°F)
•
Fan 1 speed (F1)
•
F2
•
PS status 1 (PS1) PS2
]
Response description (
XTP CrossPoint 1600
,
with
optional redundant power supply):
PS1 (12 V)
•
PS2 (48 V)
•
PS3 (12 V)
•
PS4 (48 V)
•
3.3 V
•
°F
•
Fan 1 speed (F1)
•
F2
•
PS status 1 (PS1) PS2 PS3 PS4
]
NOTE:
•
If a primary power supply that is
not
backed up by a redundant supply fails, return the matrix switcher to Extron for immediate
repairs.
•
If a backed up power supply, a redundant power supply, or a cooling fan fails, return the matrix switcher at your earliest
opportunity
.
Example
(
XTP CrossPoint 3200
):
S
See below
Fan 2 rotating at 888 RPM
12V power supply 1 at 12.01V
Temperature is 73.4 °F
All 4 power supplies installed
12.01
�
11.31
�
11.31
�
48.00
�
+3.30
�
+73.40
�
00892
�
00888
�
00892
�
01061
�
01022
�
00892
�
00888
�
1111
View all input connections
0LS
X%
1
X%
2
X%
3
...
X%
n
]
16 or 32 (
n
)
X%
s; each is the connection
status of an input, starting from input 1.
Example
(
XTP CrossPoint 3200
):
0LS
Input:
Response Status:
No input detected
Sync detected
Sync detected
1 2 3 4 5 6 7 8 9 10111213
32
0
0
0
1
1
1
0
1
0
0
1
0
1
. . .
0
NOTE:
X%
= Input signal status
0
= No signal detected
1
= Signal detected
X5!
= Voltage
Positive or negative voltage and magnitude
X5@
= Internal temperature
Degrees Fahrenheit
X5#
= Fan speed
RPM
X5$
= Power supply installation status
0
= No power supply installed
1
= Power supply installed
Symbol definitions for IP and Remote port specific SIS commands
X6!
= Matrix name
Up to 24 alphanumeric characters
NOTE:
The HTML language reserves certain characters for specific functions
X6@
=
Default name
XTP-CP-
nn
00
+ Last 3 pairs of MAC address.
nn
=
16
or
32
.
X6#
=
Time and date (for set)
In the format:
MM/DD/YY
•
HH:mm:SS
where:
MM
= month:
01
(January) to
12
(December)
DD
= day:
01
to
31
YY
= year:
00
to
99
HH
= hour:
00
to
23
mm
= minute:
00
to
59
SS
= second:
00
to
59