XTP CrossPoint Series • Programming Guide
106
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Outputs on XTP CP 4o [XTP], XTP CP 4o 4K [XTP], and XTP CP 4o Fiber 4K Boards (continued)
Ethernet serial port insert parameters (continued)
Set UART starting point
EX2!
MD
}
Pmd
X2!]
Sets the initial (lowest) port number for the
range of numbers assigned to the serial
port and UARTs.
NOTE:
Output insert port 1 is 32 positions from
X2!
for both 1600 and 3200 matrix sizes.
Read UART starting point
E
MD
}
X2!]
Outputs on XTP CP 4o [XTP] and XTP CP 4o 4K [XTP] Boards
XTP power
ATTENTION
:
•
Power over XTP (PoX) is intended for indoors use only. No part of a network that uses PoX can be routed outdoors.
•
PoX est destiné à une utilisation en intérieur uniquement. Aucune partie d’un réseau qui utilise PoX ne peut être routée en extérieur.
NOTES:
•
PoX is supplied by the matrix switcher 48 V power supply.
•
XTP CrossPoint 1600:
•
Can power up to 28 total (input and output) endpoints at up to 364 watts.
•
Is available with optional 48 V power supply redundancy.
•
XTP CrossPoint 3200:
•
Can power up to 24 total (input and output) endpoints at up to 312 watts.
•
No 48 V power supply redundancy is available.
Enable or disable power to output
endpoint and report status
E
O
X@
*
X2@
POEC
}
PoecO
X@
*
X2@
*
X2#
*
X2$]
Enable or disable (
X2@
) remote power on
output
X@
. The endpoint is requesting
X2#
watts and the power status is
X2$
.
View output power status
E
O
X@
POEC
}
X2@
*
X2#
*
X2$]
Enable or disable output power and
report status, all outputs
E
O
X2@
*POEC
}
PoecO00*
X2@
1
X2@
2
...
X2@
n
]
Each
X2@
is the enable or disable status of
an output, starting at 1.
n
is
16
or
32
.
View all output power status
E
OPOEC
}
X2@
1
X2@
2
X2@
3
...
X2@
n
]
View XTP power usage
E
TPOEC
}
X2%
*
X2^]
Show PoX wattage applied and the
status of the 48 V power supply.
NOTE
:
X@
= Output number
01
–
16
or
32
X2!
= UART starting point
The starting point (
X2!
) is the rear panel RS-232/RS-422 port.
The next position (
X2!
+1
) is not used.
For the XTP CrossPoint 1600,
X2!
+2
through
X2!
+17
are XTP inputs.
For the XTP CrossPoint 3200,
X2!
+2
through
X2!
+33
are XTP inputs.
For the XTP CrossPoint 1600 —
X2!
+18
through
X2!
+34
are XTP outputs.
For the XTP CrossPoint 3200 —
X2!
+34
through
X2!
+65
are XTP outputs.
Default values
:
1999
= Rear panel remote RS-232/RS-422 port
2001
through
2016
(
XTP CrossPoint 1600
) = Inputs
2001
through
2032
(
XTP CrossPoint 3200
) = Inputs
2033
through
2048
(
XTP CrossPoint 1600
) = Output 1 through 16
2033
through
2064
(
XTP CrossPoint 3200
) = Output 1 through 32
X2@
= Enable or disable for power
0
= Disable (
default
)
1
= Enable
X2#
= Amount of power requested
00
or
13
(watts)
X2$
= Power status
0
= Unpowered endpoint
2
= Power available but disabled
4
= Fault
1
= Power provided to endpoint
3
= No power available, but enabled
X2%
= Wattage
Power usage in 0.1 watt increments. Example:
260
= 26.0 watts
X2^
= Power supply status
0
= Ok
1
= Not Ok