4-7
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
Spr
nn
]
The switcher initiates the Spr message when a preset has been saved from the front
panel.
nn
is the preset number.
Rpr
nn
]
The switcher initiates the Rpr message when a preset has been recalled from the
front panel.
nn
is the preset number.
In
nn
•Aud
xx
]
The switcher initiates the Aud message when a front panel input audio level change
has occurred.
nn
is the input number and
xx
is the dB level.
Out
nn
•Vol
xx
]
The switcher initiates the Vol message when a front panel output audio volume
change has occurred.
nn
is the output number and
xx
is the volume level.
Vmt
nn
•
x
]
The switcher initiates the Vmt message when a video output mute is toggled on
or off from the front panel. “
nn
” is the output number, • is a space, and “
x
” is the
mute status: 1 = on, 0 = off.
Amt
nn
•
x
]
The switcher initiates the Amt message when an audio or RS-232 output mute is
toggled on or off from the front panel.
nn
is the output number, • is a space, and
x
is the mute status: 1 = on, 0 = off.
Exe
n
]
The switcher initiates the Exe message when executive mode is toggled on or off
from the front panel.
n
is the executive mode: 0, 1, or 2.
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher
is unable to perform the command because the command is invalid or contains
invalid parameters, the switcher returns an error response to the host. The error
response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this configuration
E17 — Timeout (caused only by direct write of global presets)
E21 — Invalid room number
E22 — Busy
E24 — Priviledge violation (Users have access to all view and read
commands (other than the Adminstrator password), and can
create ties, presets, and video and audio mutes
E25 — Device not present
E26 — Maximum number of connections exceeded
E27 — Invalid event number
E28 — Bad filename / file not found
Summary of Contents for CrossPoint 450 Plus 2412 HV
Page 4: ......
Page 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Page 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Page 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Page 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Page 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Page 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Page 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...