3-55
CrossPoint / MAV Matrix Switchers • Operation
2
.
Release the Control buttons.
N
The serial port settings are protected when front panel
Lock
mode 2 is selected.
You can view the settings in
Lock
mode 2 but you cannot change them from
the front panel. See “Setting the front panel Locks (
page 3-52.
If front panel
Lock
mode 2 is selected and you try to perform step
3
, the actions
are ignored and the Enter, Video, and Audio buttons flash.
3
.
To change a value
, press and release the button that relates to the desired
value (figure 3-80).
C O N T R O L
PRESET
ENTER
I / O
RGBHV AUDIO
ESC
VIEW
Press and release the button(s) to configure the port as
follows:
Baud rate:
Enter — 9600
Preset — 19200
View — 38400
Esc — 115200
Serial protocol:
RGBHV/Video — RS-232
Audio — RS-422/RS-485
The selected buttons blink and the others remain lit.
In this example, the port is set to RS-422 at 38400 baud.
Figure 3-80 — RS-232/RS-422 and baud rate selection
4
.
Press and release an output button to exit the
Serial Port Selection and
Configuration
mode (figure 3-81).
C O N T R O L
PRESET
ENTER
I / O
RGBHV AUDIO
ESC
VIEW
5
All Control and I/O buttons return to unlit or background illumination.
Press and release an
input or output button.
Figure 3-81 — Exit
Serial Port Selection and
Configuration
mode
Rear Panel Operations
The rear panel has a Reset button that initiates four levels of resets
(numbered 1, 3, 4, and 5 for the sake of comparison with an Extron IPL
product). The Reset button is recessed, so use a pointed stylus, ballpoint
pen, or Extron Tweeker to access it.
See the following table for a summary of the modes.
C
Review the reset modes carefully. Using the wrong reset mode may result
in unintended loss of flash memory programming, port reassignment, or a
controller reboot.
N
The reset modes listed below close all open IP and Telnet connections and close
all sockets. Also, the following modes are separate functions, not a continuation
from Mode 1 to Mode 5.
RESET
LAN
Summary of Contents for CrossPoint 450 Plus 2412 HV
Page 4: ......
Page 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Page 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Page 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Page 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Page 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Page 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Page 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...