Operation, cont’d
CrossPoint / MAV Matrix Switchers • Operation
3-56
Reset Mode Comparison/Summary
Mode
Activation
Result
Purpose/Notes
1
Hold down the recessed Reset button
while applying power to the switcher.
N
After a mode 1 reset is
performed, update the
switcher’s firmware to the
latest version. Do not operate
the switcher firmware version
that results from the mode
1 reset. If you want to use
the factory default firmware,
you must upload that version
again. See chapter 5, “Matrix
Software”, for details on
uploading firmware.
The switcher reverts to the factory default
firmware.
Event scripting will not start if the
switcher is powered on in this mode. All user files
and settings (drivers, adjustments, IP settings, etc)
are maintained.
N
If you do not want to update firmware, or
you performed a mode 1 reset by mistake,
cycle power to the switcher to return to the
firmware version that was running before
the mode 1 reset. Use the 0Q SIS command
to confirm that the factory default firmware
is no longer running (look for the asterisk
[*] following the version number.
Use mode 1 to revert
to the factory default
firmware version if
incompatibility issues
arise with user-loaded
firmware.
3
Hold down the Reset button for about
3 seconds, until the Reset LED blinks
once, then press Reset momentarily
(<1 second) within 1 second.
Mode 3 turns events on or off.
During resetting,
the Reset LED flashes 2 times if events are starting,
3 times if events are stopping.
Mode 3 is useful for
troubleshooting.
4
Hold down the Reset button for
about 6 seconds, until the Reset LED
blinks twice (once at 3 seconds and
again at 6 seconds). Then press Reset
momentarily (<1 second) within 1
second.
Mode 4:
• Enables ARP capability.
• Sets the IP address to the factory default.
• Sets the subnet address to the factory default.
• Sets the gateway address to the factory default.
• Sets port mapping to the factory default.
• Turns DHCP off.
• Turn events off.
The Reset LED flashes four times in quick
succession during the reset.
Mode 4 enables you
to set IP address
information using ARP
and the MAC address.
5
Hold down the Reset button for
about 9 seconds, until the Reset LED
blinks three times (once at 3 seconds,
again at 6 seconds, and then again
at 9 seconds). Then press Reset
momentarily (<1 second) within 1
second.
N
Mode 5 reset clears most
adjustments. To save these
settings, use the Windows-
based Matrix Switchers
Control Program and the
you perform this reset (See
chapter 5, “Matrix Software”).
Mode 5 performs a complete reset to factory
defaults (with the exception of the firmware):
• Does everything mode 4 does.
• Resets almost all real time adjustments:
clears all ties and presets, clears all audio or
RS-232 mutes, clears all I/O grouping, clears
all RGB delay settings to zero, and clears all
input and output audio settings.
• Resets all IP options.
• Removes/clears all files for the switcher.
The reset LED flashes four times in quick
succession during the reset.
Mode 5 is useful if
you want to start over
with configuration and
uploading and also to
replace events.
For different reset levels, press and hold the button while the switcher is running or
press and hold the button while you apply power to the switcher.
Summary of Contents for CrossPoint 450 Plus 2412 HV
Page 4: ......
Page 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Page 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Page 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Page 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Page 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Page 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Page 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...