CrossPoint / MAV Matrix Switchers • Installation
2-2
Installation
Mounting the Switcher
The matrix switchers are housed in rack-mountable, metal enclosures with 19" rack
ears. The amount of vertical rack space required for each switcher is as follows:
• 2U high enclosure
MAV Plus 84, 88, 124, and 128 HDA and HD
MAV Plus 84, 88, 124, 128, and 1212 SVA, and SV
MAV Plus 84, 88, 124, 128, 816, 1212, 168, and 1616 AV, AV RCA, V, and A
MAV Plus 164 A
• 3U high enclosure
CrossPoint Ultra 84, 88, 124, and 128 HV and HVA
MAV Plus 168, 816, 1212, and 1616 SVA and SV
• 4U high enclosure
MAV Plus 168, 816, and 1616 HDA and HD
• 5U high enclosure
MAV Plus 2412, 2424, 3216, 3232 AV, V, and A
• 6U high enclosure
CrossPoint Ultra 816, 168, 1212, and 1616 HV and HVA
• 8U high enclosure
CrossPoint 450 Plus 2412 and 2424 HV and HVA
• 10U high enclosure
CrossPoint 450 Plus 3216 and 3232 HV and HVA
UL guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the installation
of the matrix switcher into a rack (figure 2-1).
1.
Elevated operating ambient temperature
— If installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consider
installing the equipment in an environment compatible with the maximum
122 °F (50 °C) (CrossPoint) or 113 °F (45 °C) (MAV Plus) ambient temperature
(Tma) specified by Extron.
2.
Reduced air flow
— Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not
compromised.
3.
Mechanical loading
— Mounting of the equipment in the rack should be such
that a hazardous condition is not achieved due to uneven mechanical loading.
4.
Circuit overloading
— Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when
addressing this concern.
5.
Reliable earthing (grounding)
— Reliable earthing of rack-mounted
equipment should be maintained. Particular attention should be given to
supply connections other than direct connections to the branch circuit (e.g. use
of power strips.
Summary of Contents for CrossPoint 450 Plus 2412 HV
Page 4: ......
Page 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Page 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Page 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Page 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Page 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Page 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Page 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...