Programmer’s Guide, cont’d
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
4-18
Command/response table for SIS commands (continued)
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
I/O Grouping (continued)
N
X1^
= Group # (for I/O grouping)
1 through 4 groups (0 = no group)
Read input grouping
E
I
}
X1^
1
X1^
2
X1^
3
...
X1^
n
]
Each
X1^
entry is the group
number assigned to an input
position, starting from input 1.
n
= the maximum number of
inputs for this model.
Example:
MAV Plus 2424
E
I
}
See below.
01
Input:
Response = group:
Input 1 in group 1
02 03 04 05 06 07 08 09 10 11 12
1 1 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3
13 14 15 16 17 18 19 20 21 22 23 24
Input 9 not grouped
Input 24 in group 3
Read output grouping
E
O
}
X1^
1
X1^
2
X1^
3
...
X1^
n
]
Each
X1^
entry is the group
number assigned to an output
position, starting from output
1.
n
= the maximum number
of outputs for this model.
Names
N
X(
= Global or room preset #
00 - 32, 10 maximum for a room preset (00 = current configuration)
X1!
= Name
11 (rooms) or 12 characters (inputs, outputs, and global presets)
11 characters maximum for room names
X1)
= Room # (for room presets)
10 maximum
X!
= Input number
01 – (maximum number of inputs for your model)
Write global preset name
EX(
,
X1!
NG
}
Nmg
X(
,
X1!]
Example:
E
1,Security 1NG
}
Nmg01
,
Security 1
]
Name global preset 1
“Security 1”.
Read global preset name
EX(
NG
}
X1!]
Example:
E
2NG
}
Security 2
]
Write room name
EX1)
,
X1!
NR
}
Nmr
X1)
,
X1!]
Example:
E
1
,
Classrm 1NR
}
Nmr01
,
Classrm 1
]
Name room 1 “Classrm 1”.
Read room name
EX1)
NR
}
X1!]
Write room preset name
EX1)
*
X(
,
X1!
NP
}
Nmp
X1)
*
X(
,
X1!]
Example:
E
1*3
,
Podium_DVDNP
}
Nmp01*3
,
Podium_DVD
]
Name room 1, preset 3
“Podium_DVD”.
Read room preset name
EX1)
,
X(
NP
}
X1!]
N
• Do not use leading spaces in preset names.
•
If a preset is unassigned, the
X1!
displays
[unassigned]
.
•
If a global preset is saved, but not yet named, the default name is
Preset
X(
.
•
If a room preset is saved, but not yet named, the default name is
Rm
X1)
Prst
X(
.
Write input name
EX!
,
X1!
NI
}
Nmi
X!
,
X1!]
Example:
E
1
,
Podium camNI
}
Nmi01
,
Podium cam
]
Name input 1 “Podium cam”.
Read input name
EX!
NI
}
X1!]
Write output name
EX!
,
X1!
NO
}
Nmo
X!
,
X1!]
Example:
E
1,Main PJ1NO
}
Nmo01,Main PJ1
]
Name output 1 “Main PJ1”.
Read output name
EX!
NO
}
X1!]
Summary of Contents for CrossPoint 450 Plus 2412 HV
Page 4: ......
Page 22: ...Introduction cont d CrossPoint MAV Matrix Switchers Introduction 1 12...
Page 44: ...Installation cont d CrossPoint MAV Matrix Switchers Installation 2 22...
Page 108: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 64...
Page 110: ...Operation cont d CrossPoint MAV Matrix Switchers Operation 3 66...
Page 162: ...Matrix Software cont d CrossPoint MAV Matrix Switchers Matrix Software 5 26...
Page 190: ...Ethernet Connection cont d CrossPoint MAV Matrix Switchers Ethernet Connection A 8...
Page 212: ...Reference Information cont d CrossPoint MAV Matrix Switchers Reference Information B 22...