show fdb
ExtremeWare 7.5 Command Reference Guide
425
Example
The following command displays information about all the entries in the FDB:
show fdb
It produces output similar to the following:
Index Mac Vlan Age Use Flags Port List
------------------------------------------------------------------------
0a0e0-100 00:01:30:EC:D3:00 lab(4000) 0000 0001 d i 1
2b560-ffb 01:00:0C:CC:CC:CD (0000) 0000 0000 s m CPU
30040-ffb 00:E0:2B:00:00:00 zzz(0652) 0000 0000 s m CPU
332890-ffb 00:E0:2B:00:00:00 Default(0001) 0000 0000 s m CPU
3d760-ffb 00:E0:2B:00:00:00 Mgmt(4094) 0000 0000 s m CPU
3d770-ffb 00:E0:2B:00:00:00 MacVlanDis(4095) 0000 0000 s m CPU
42560-ff0 00:01:30:6C:0D:00 lab(4000) 0000 0000 s m CPU
46460-100 00:10:E3:1D:00:1E lab(4000) 0000 0001 d i 1
4d060-100 00:10:E3:1D:00:05 lab(4000) 0000 0001 d i 1
4df70-ff0 00:01:30:6C:0D:00 Default(0001) 0000 0000 s m CPU
4f7a0-ff0 00:01:30:6C:0D:00 zzz(0652) 0000 0000 s m CPU
51f50-100 00:01:30:CA:F6:00 lab(4000) 0000 0001 d i 1
...
67b20-100 00:30:D3:01:5A:E0 lab(4000) 0000 0001 d i 1
80a10-204 FF:FF:FF:FF:FF:FF lab(4000) 0000 0000 s m CPU, 2, 1
80fe0-208 FF:FF:FF:FF:FF:FF MacVlanDis(4095) 0000 0000 s m CPU
80ff0-202 FF:FF:FF:FF:FF:FF Mgmt(4094) 0000 0000 s m CPU
8d8d0-20a FF:FF:FF:FF:FF:FF zzz(0652) 0000 0000 s m CPU, 2
8f000-200 FF:FF:FF:FF:FF:FF Default(0001) 0000 0000 s m CPU
98670-100 00:01:30:E7:F2:00 lab(4000) 0000 0001 d i 1
fcf70-202 00:E0:2B:00:00:02 Mgmt(4094) 0000 0000 s m CPU
Flags: (B) Egress Blackhole, (b) Ingress Blackhole, (d) Dynamic, (s) Static
(p) Permanent, (m) MAC, (S) secure MAC, (l) lockdown MAC, (M) Mirror
(i) IP, (x) IPX, (z) translation MAC, (Q) Questionable, (R) Remapped
Flags
Flags that define the type of entry:
•
B - Egress Blackhole
•
b - Ingress Blackhole
•
d - Dynamic
•
s - Static
•
p - Permanent
•
m - MAC
•
S - secure MAC
•
l - lockdown MAC
•
M - Mirror
•
i - an entry also exists in the IP FDB
•
x - an entry also exists in the IPX FDB
•
z - translation MAC
•
Q - Questionable
•
R - Remapped
Port List
The ports on which the MAC address has been learned
Summary of Contents for ExtremeWare 7.5
Page 402: ...402 ExtremeWare 7 5 Command Reference Guide VLAN Commands ...
Page 470: ...470 ExtremeWare 7 5 Command Reference Guide QoS Commands ...
Page 490: ...490 ExtremeWare 7 5 Command Reference Guide NAT Commands ...
Page 826: ...826 ExtremeWare 7 5 Command Reference Guide Commands for Status Monitoring and Statistics ...
Page 1090: ...1090 ExtremeWare 7 5 Command Reference Guide Security Commands ...
Page 1386: ...1386 ExtremeWare 7 5 Command Reference Guide Wireless Commands ...
Page 1436: ...1436 ExtremeWare 7 5 Command Reference Guide EAPS Commands ...
Page 1568: ...1568 ExtremeWare 7 5 Command Reference Guide ESRP Commands ...
Page 1844: ...1844 ExtremeWare 7 5 Command Reference Guide IGP Commands ...
Page 1930: ...1930 ExtremeWare 7 5 Command Reference Guide BGP Commands i Series Switches Only ...
Page 2022: ...2022 ExtremeWare 7 5 Command Reference Guide IP Multicast Commands ...
Page 2066: ...2066 ExtremeWare 7 5 Command Reference Guide IPX Commands i Series Platforms Only ...
Page 2082: ...2082 ExtremeWare 7 5 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Page 2094: ...2094 ExtremeWare 7 5 Command Reference Guide Remote Connect Commands ...
Page 2174: ...2174 ExtremeWare 7 5 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Page 2372: ...2372 ExtremeWare 7 5 Command Reference Guide LLDP Commands ...
Page 2422: ...2422 ExtremeWare 7 5 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Page 2528: ...2528 ExtremeWare 7 5 Command Reference Guide MPLS Commands BlackDiamond Switch Only ...