BlackDiamond 600/900 W AC PSU, Model 41050/PS 2431:
•
The power supply cord must be agency-certified for the country of use.
•
The power supply cord must have an IEC 320 C13 plug to connect to the IEC320 C14 connector on
the power supply.
•
The power supply cord must have an appropriately rated and approved wall plug applicable to the
country of installation.
•
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm2) minimum; over 6 feet, the
minimum wire size is 16 AWG (1.0 mm2).
Black Diamond SSI DC PSU, Model 60021:
•
The wire must be UL Listed Type TC (Tray Cable), three conductor, 8 AWG, jacketed, and marked
(UL) TC, 90C min.
Note
Tray Cable is a UL requirement only in the USA. Outside the United States, standard 8 AWG
(8.35mm2), 90C wire is acceptable.
•
There is no wall plug; 3-conductor wires have been stripped and are ready for connection to DC
power source mains.
•
The device connector is a Molex Shell Connector PN 42816-0312; Molex Pin Connectors PN
42815-0032.
•
The assembly rating is 75VDC, 30A, (Do not disconnect under load).
Note
This equipment is not intended to be directly powered by power distribution systems where
phase-phase voltages exceed 240V AC (2P+PE), such as those used in Norway, France, and
other countries. For these applications it is recommended that a transformer be used to step
down the voltage to < 240V AC from phase-phase, or that you make a connection to a (P+N
+PE) power distribution where voltages do not exceed 240V AC.
All installations should confirm that the product is reliably grounded according to the
country’s local electrical codes.
Battery Replacement and Disposal
Batteries included with Extreme products are encapsulated and must be replaced only by qualified
Extreme Service personnel. Contact your Extreme Networks Service personnel for product replacement.
Do not attempt to replace the battery. If these instructions are disregarded and replacement of these
batteries is attempted, the following guidelines must be followed to avoid danger of explosion:
•
Replace with the same or equivalent battery type as recommended by the battery manufacturer.
•
Dispose of the battery in accordance with the battery manufacturer’s recommendation.
Fiber Optic Ports—Optical Safety
The following safety warnings apply to all optical devices used in Extreme Networks equipment that are
removable or directly installed in an I/O module or chassis system. Such devices include but are not