Setting Up Copper Tests
58
MAX-610
Cable Book
Cable Details
The
Cable Details
page allows you to view the cable
parameter details of the currently highlighted cable
entry.
Cable ID
displays the cable ID number.
Cable Name
is the name of the cable in the
Cable
Book
.
Cable Gauge
is the gauge system for measuring
wire sizes in AWG (American Wire Gauge) units
or mm (metric wire size).
Cable Fill
is the type of material the cable is filled
with:
Aircore
,
Jelly
,
Pulp
,
5 PR
, or
2 PR
.
Capacitance T-R/A-B
specifies a value for the capacitance per length
constant.
Capacitance T/R to GND/A/B to E
specifies a value for the capacitance
per length to ground constant.
Resistance
specifies a value for the resistance constant of the cable.
Attenuation @ 300 kHz
specifies a value for the reduction in signal
strength or insertion loss of the cable.
VOP
is the velocity of propagation for the cable as a ratio of the speed
of light.
Temperature
specifies the temperature of reference at which all cable
parameters have been measured, in either F (Fahrenheit) or C
(Celsius) units. The measurement units are updated based on the
Temperature
settings in
Setup
/
Application Settings
/
Standard
.