Multimeter Tests
102
MAX-610
Current
To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options.
4.
Press
to confirm the value.
Continuous DC Page
The
Continuous DC
function measures each pair,
displaying and updating results in
real time
, until you
stop the test. The last valid results then remain
displayed.
Continuous AC
and
Continuous DC
are run
synchronously.
Press Start/Stop on the keypad to run the test.
Current Group
is the current test group name, for
example
Multimeter
.
Current Test
displays the test being measured.
Here you can switch to another test from the given list. However, this
action will terminate the ongoing measurement test.
Selected Pair
allows you to select
All Pairs
or a single wire pair for
measurement.
Termination Resistance
is a read-only value of
430
Ω
that defines how
much resistance the tester uses to connect to the line.
Threshold Settings
button opens a new page that allows you to set the
DC current thresholds for each pair.